Sign up to set email alerts
|

Reverse solar envelope method. A new building form-finding method that can take regulatory frameworks into account

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 37 publications
0
14
0
Order By: Relevance
“…The proposed reverse passive design approach is based on the use of computational design optimization. A similar reverse design approach has been proposed by Luca et al (2021), which focuses on solar envelope buildings. Luca's approach, nevertheless, is developed for a specific type of passive building typologies, which limits its applicability for general passive building design.…”
Section: Methodsmentioning
confidence: 99%
“…The proposed reverse passive design approach is based on the use of computational design optimization. A similar reverse design approach has been proposed by Luca et al (2021), which focuses on solar envelope buildings. Luca's approach, nevertheless, is developed for a specific type of passive building typologies, which limits its applicability for general passive building design.…”
Section: Methodsmentioning
confidence: 99%
“…Although, there are several building massing methods that take into account the solar access of both, existing and new buildings (Capeluto and Shaviv, 2001;De Luca and Dogan, 2019;De Luca, Dogan and Sepúlveda, 2021). There is a lack of building massing methods based on simultaneously energy performance and solar access of the surrounding buildings that could be used as a negotiation tool by designers without the need of time-consuming energy simulations.…”
Section: Novelty and Aims Of This Researchmentioning
confidence: 99%
“…In practice, due to the non-mandatory nature of daylight standards in most countries, the designer would have flexibility to define a building massing even if the volume of the new building does not guarantee the same SA level for all the surrounding buildings. Indeed, the recently developed method called Reverse Solar Envelope allows the consideration of a certain maximum obstruction index (OI) for each cell of the theoretical block (generated by the extrusion of the buildable plot to a maximum buildable height) (De Luca, Dogan and Sepúlveda, 2021). Moreover, energy performance and solar radiation have been considered as objectives in previous studies developed through focused on multi-objective optimization (Wang, Song and Tang, 2020;Natanian and Wortmann, 2021;Xia and Li, 2021).…”
Section: Introductionmentioning
confidence: 99%
“…Sun altitudes and solar azimuth values in annexe tables in EN 17037 are used to filter in only those sun vectors that contribute to direct sunlight for standard compliance. New methods of assessment of solar access and solar envelopes have been proposed recently (de Luca et al, 2021), and are implemented in the plugin the 'Solar Envelope Tools' from Tallinn University of Technology. However, such workflows can only be applied in a defined urban condition for controlling the new building shape.…”
Section: Exposure To Sunlightmentioning