2015
DOI: 10.1016/j.jse.2015.04.015
|View full text |Cite
|
Sign up to set email alerts
|

Reverse shoulder arthroplasty for massive rotator cuff tear: risk factors for poor functional improvement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
66
2
2

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 127 publications
(72 citation statements)
references
References 51 publications
0
66
2
2
Order By: Relevance
“…Observa-se na literatura uma maior porcentagem para procedimentos artroscópicos. [43][44][45] Após procedimentos cirúrgicos, um bom instrumento de avaliação, completo e confiável que pode ser utilizado é o escore de UCLA. 46,47…”
Section: Methodsunclassified
“…Observa-se na literatura uma maior porcentagem para procedimentos artroscópicos. [43][44][45] Após procedimentos cirúrgicos, um bom instrumento de avaliação, completo e confiável que pode ser utilizado é o escore de UCLA. 46,47…”
Section: Methodsunclassified
“…It is possible to medialize the sutures if necessary. It is preferable not to reinsert the subscap if it is too tight [65,[69][70][71][98][99][100] .…”
Section: Humeral Componentsmentioning
confidence: 99%
“…However, surgical treatment remains a challenge due to technical difficulties and unpredictability of the results of the repair [41,42] , which led orthopedic surgeons to look for alternative options to treat MCT Many palliative interventions have been proposed, including, tendon transfers [17,37,38] , long head of the biceps tenotomy or tenodesis [43] , subacromial decompression [44] , subacromial balloons, partial rotator cuff repair [45][46][47] , superior capsular reconstruction [51][52][53][54] , hemiarthroplasty or total shoulder prosthesis constrained or not [55][56][57][58][59][60][61][62] and reverse shoulder arthroplasty [63][64][65][66][67][68][69] .…”
Section: Introductionmentioning
confidence: 99%
“…Die Implantatsysteme sind in ständiger Weiterentwicklung und haben einen hohen technischen Standard erreicht (modular, konvertierbar, individualisierbar, Teilwechsel möglich, Knochenaufbau möglich). Obwohl der Einsatz von inversen Schulterendoprothesen für irreparable RM-Läsionen ohne Gelenkzerstörung beschrieben wurde, sollte aus prinzipiellen Erwägungen im Hinblick auf die Langzeitprognose und Standzeiten aus Sicht der Autoren in dieser Indikation äußerste Zurückhaltung vorherrschen (61)(62)(63).…”
Section: Inverse Schulterendoprothetikunclassified