2015
DOI: 10.13075/ijomeh.1896.00325
|View full text |Cite
|
Sign up to set email alerts
|

Reverse phase high performance liquid chromatographic method development based on ultravioletvisible detector for the analysis of 1-hydroxypyrene (PAH biomarker) in human urine

Abstract: Objectives: 1-hydroxypyrene is an important biomarker of exposure to polycyclic aromatic hydrocarbons (PAHs), which appears in the urine of exposed human subjects. In developing countries, where advanced instruments are not available, the importance of this biomarker demands convenient and sensitive methods for determination purposes. This study aimed at developing a methodology to quantify 1-hydroxypyrene (a biomarker of PAHs exposure) based on the UV-visible detector in the reverse phase high pressure liquid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…The estimation of urinary 1-HOP was done using high-performance liquid chromatography (HPLC) as previously described. The concentration of urinary 1-HOP was adjusted to urinary creatinine excretion (µg/g creatinine) to correct for urine flow rate ( 15 ).…”
Section: Methodsmentioning
confidence: 99%
“…The estimation of urinary 1-HOP was done using high-performance liquid chromatography (HPLC) as previously described. The concentration of urinary 1-HOP was adjusted to urinary creatinine excretion (µg/g creatinine) to correct for urine flow rate ( 15 ).…”
Section: Methodsmentioning
confidence: 99%
“…Standard chemicals (berberine, magnolol, and morroniside) were purchased from the National Institutes for Food and Drug Control (NIFDC). Briefly, the quality of SHTXF was determined using a high-performance liquid chromatography (HPLC) system equipped with a UV-visible detector ( Kamal et al, 2015 ). The analysis was performed using a Shimadzu LC-20A instrument.…”
Section: Methodsmentioning
confidence: 99%
“…For high pressure liquid chromatography (HPLC) analysis procedures described by Iqbal, Alam, and Anwer () and Kamal, Gulfraz, Asad, and Malik () were followed. The HPLC conditions were optimized by running a series of standard dilutions for a number of times and the conditions were observed for three consecutive days to validate optimization.…”