2023
DOI: 10.1016/j.carbon.2023.118271
|View full text |Cite
|
Sign up to set email alerts
|

Revealing the interlayer orientations for bilayer graphene grown on hexagonal boron nitride by c-AFM measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 39 publications
0
3
0
Order By: Relevance
“…The highest responsivity and detectivity were confirmed at the 830 nm point, and the responsivity of the transferred PEDOT:PSS patch device is 0.55 A W –1 (0.53 A W –1 in the spin-coated condition) and the detectivity is 5.12 × 10 12 Jones (2.56 × 10 12 Jones in the spin-coated condition) (Figure e,f, and Table ). These efficient dark current suppression outcomes were due to the reduction of charge carrier recombination and trap-assisted recombination achieved by the stabilized surface of the transferred PEDOT:PSS patch and tuned energy level. , …”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The highest responsivity and detectivity were confirmed at the 830 nm point, and the responsivity of the transferred PEDOT:PSS patch device is 0.55 A W –1 (0.53 A W –1 in the spin-coated condition) and the detectivity is 5.12 × 10 12 Jones (2.56 × 10 12 Jones in the spin-coated condition) (Figure e,f, and Table ). These efficient dark current suppression outcomes were due to the reduction of charge carrier recombination and trap-assisted recombination achieved by the stabilized surface of the transferred PEDOT:PSS patch and tuned energy level. , …”
Section: Resultsmentioning
confidence: 99%
“…Figure c,d shows the conductive AFM (C-AFM) images of the spin-coated PEDOT:PSS electrode and transferred PEDOT:PSS patch. C-AFM is a measurement method that can confirm the conductivity of the surface by detecting the higher current value flowing between the cantilever and the sample at a constant cantilever voltage . The C-AFM image of the transferred PEDOT:PSS patch is a green-dominant image (with current intensities ranging from 100 to 200 nA), while the spin-coated PEDOT:PSS electrode image yields a blue-dominant image (with current intensities ranging from 0 to 100 nA) because the conductive phase of the PEDOT dominant domain was come up through phase switching in the transferred PEDOT:PSS patch.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation