ASME 2010 4th International Conference on Energy Sustainability, Volume 1 2010
DOI: 10.1115/es2010-90213
|View full text |Cite
|
Sign up to set email alerts
|

Revamping, Energy Efficiency and Exergy Analysis of an Existing Upstream Gas Treatment Facility

Abstract: Surface oil and gas treatment facilities in service for decades are likely to be oversized due to the natural depletion of their reservoirs. Despite these plants might have been designed modularly, meaning they comprise multiple identical units serving the same task, such units operate often in conditions far from the design point and inefficiently. This work analyzes the revamping options of an existing upstream gas facility, which is chosen because representative of a wide set of plants. A flexible numerical… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2012
2012
2014
2014

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Exergy is usually considered for machines that deal with heat and mechanical work [32,33] though the term is also valid for electrochemical systems [34] and is the electric work that is available when considering tbe process as a whole. Exergy efficiency is then defined as how much of the available work one gets out of the system when accounting for all losses.…”
Section: Theorymentioning
confidence: 99%
“…Exergy is usually considered for machines that deal with heat and mechanical work [32,33] though the term is also valid for electrochemical systems [34] and is the electric work that is available when considering tbe process as a whole. Exergy efficiency is then defined as how much of the available work one gets out of the system when accounting for all losses.…”
Section: Theorymentioning
confidence: 99%
“…The specific exergy waste reflects the losses of resources with the flared and vented gases, but also with the produced water, which is rejected in significant quantities for platforms operating on mature oilfields. It would also be relevant to compare the current power consumption with the power demand when integrating best-available-technologies, as this provides information on the maximum energy savings with the current technological limits [82].…”
Section: Benchmarking and Performance Indicatorsmentioning
confidence: 99%
“…• Margarone et al [62], who proposed to compare the current plant performance against that obtainable when integrating the state-of-the-art technologies present on the market;…”
Section: Theoretical Versus Practical Improvement Potentialmentioning
confidence: 99%