2016
DOI: 10.2144/000114450
|View full text |Cite
|
Sign up to set email alerts
|

Reuse of E-Plate Cell Sensor Arrays in the xCELLigence Real-Time Cell Analyzer

Abstract: The xCELLigence Real-Time Cell Analyzer (RTCA) is a non-invasive, impedence-based biosensor system that can measure cell viability, migration, growth, spreading, and proliferation. Changes in cell morphology and behavior are continuously monitored in real time using microelectronics located in the wells of RTCA E-plates. According to the manufacturer's recommendation, E-plates are single-use and disposable. Here, we show that E-plates can be regenerated and reused several times without significantly effecting … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(24 citation statements)
references
References 27 publications
(17 reference statements)
0
23
0
Order By: Relevance
“…RTCA is a non‐invasive, impedance‐based biosensor system that can measure cell viability, migration, growth, spreading and proliferation. Changes in cell morphology and behaviour are continuously monitored in real time using microelectronics located in the wells of the RTCA E‐plates (Stefanowicz‐Hajduk et al ., ). As cells adhere to the biocompatible gold microelectrodes that line the well bottoms in an E‐plate, they impede the flow of electric current between electrodes.…”
Section: Methodsmentioning
confidence: 97%
“…RTCA is a non‐invasive, impedance‐based biosensor system that can measure cell viability, migration, growth, spreading and proliferation. Changes in cell morphology and behaviour are continuously monitored in real time using microelectronics located in the wells of the RTCA E‐plates (Stefanowicz‐Hajduk et al ., ). As cells adhere to the biocompatible gold microelectrodes that line the well bottoms in an E‐plate, they impede the flow of electric current between electrodes.…”
Section: Methodsmentioning
confidence: 97%
“…Cells (Ishikawa, AN3CA and HEC1A) were seeded in E-plate 96 (ACEA Biosciences) at 10,000 cells/well in the corresponding medium supplemented with 5% FCS and the plate was monitored every 1 min for 5 h, then every 15 min for a total of 72 h (24). E-plates were used a maximum of 3 times, with the wells trypsinized and washed with PBS between each use, as previously described (25). Data was calculated using RTCA software 1.2, supplied with the instrument (ACEA Biosciences, San Diego, CA, USA; https://www.aceabio.com/products/xcelligence-rtca/) and exported for statistical analysis.…”
Section: Methodsmentioning
confidence: 99%
“…The x CELLigence® RTCA DP system (Roche Applied Science, Penzberg, Germany) was used to automatically and continuously monitor live cell proliferation, growth, viability, migration, and spreading with characters of non-invasive, close to physiological status, a higher degree of accuracy, and lab free [29,30]. The cells transfected with siRNA-Control or si-BRWD3 were seeded on an E-plate- 16 Chromatin immunoprecipitation combining with Sequencing (ChIP-seq) assay…”
Section: Cell Proliferation and Invasion Detected With The Xcelligencmentioning
confidence: 99%