2014
DOI: 10.1016/j.btre.2014.06.003
|View full text |Cite
|
Sign up to set email alerts
|

Reusable urine glucose sensor based on functionalized graphene oxide conjugated Au electrode with protective layers

Abstract: An electrochemical based system with multiple layers coated on a functionalized graphene oxide Au electrode was developed to measure glucose concentration in urine in a more stable way. Two types of gold printed circuit boards were fabricated and graphene oxide was immobilized on their surface by chemical adsorption. Multiple layers, composed of a couple of polymers, were uniformly coated on the surface electrode. This device exhibited higher electrochemical responses against glucose, a greater resistivity in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
10
0

Year Published

2016
2016
2019
2019

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 18 publications
(20 reference statements)
1
10
0
Order By: Relevance
“…Hydrophilic treatment was performed using an oxygen plasma in a CUTE chamber (Femto Science, Republic of Korea). Electrochemical immunoassay measurements were performed on a VersaSTAT 3 potentiostat/galvanostat (Ametek, Princeton Applied Research, USA) with a custom-made Au-printed circuit board (PCB) sensor 40 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Hydrophilic treatment was performed using an oxygen plasma in a CUTE chamber (Femto Science, Republic of Korea). Electrochemical immunoassay measurements were performed on a VersaSTAT 3 potentiostat/galvanostat (Ametek, Princeton Applied Research, USA) with a custom-made Au-printed circuit board (PCB) sensor 40 .…”
Section: Methodsmentioning
confidence: 99%
“…The customized Au-PCB (d = 2 mm) sensor employed in the present experiment was surface-cleaned by isopropanol and rinsed thoroughly with DIW. Before performing any surface modification, the Au-PCB working surface was treated with oxygen plasma for 2 min 40 . The Au electrode was pretreated with O 2 plasma at a base pressure of 5 × 10 −2 Torr, a working pressure of 7.8 × 10 −1 Torr, 50 watts power, and an oxygen flow rate of 45 sccm for 2 min.…”
Section: Methodsmentioning
confidence: 99%
“…Such combined properties enhance fast electron transfer, enabling its application in electrochemical sensing and biosensing. In order to increase its sensitivity and selectivity, GO usually is functionalised with other materials, such as nanoparticles or polymers [16][17][18][19][20][21]. At present, several of the recent studies have combined gold nanoparticles with graphene-based materials for electrochemical sensors and biosensors, trying to take advantage of the catalytic character and biocompatibility of gold.…”
Section: Introductionmentioning
confidence: 99%
“…Benvidi et al fabricated a reduced graphene oxide (RGO), gold nanoparticles and 2-(3,4-dihydroxyphenyl)benzothiazole-modified glassy carbon electrode for the simultaneous determination of levodopa, uric acid and folic acid [17]. Only a few publications may be found related with modified interdigitated arrays [21,25] or screen-printed electrodes [19], with a small size which makes the development of portable Lab-on-a-Chip devices feasible.…”
Section: Introductionmentioning
confidence: 99%
“…Urine has been widely studied as a glucose diagnostic sample because it is easily and noninvasively collected. [1][2][3] Persistent high glucose levels in urine may increase the complications from diabetes or indicate a poor response to treatment. Urine glucose in the 2.78-5.55 mM range reliably indicates that blood sugar levels are high.…”
Section: Introductionmentioning
confidence: 99%