Return of the dedicated DFR: how IEC 61850 process bus simplifies DFR installation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…The correlation coefficient and relative error between the reformulated SCC waveform expressed by Equation ( 21) and the original one by Equation ( 1) are respectively calculated by Equation ( 5) and (6), which are: cxy = 0.999 980 063 830 419, ε = 3.987 194 171 128 92 × 10 −5 The curve of the absolute errors of the reformulated SCC is shown in Figure 13, where the maximum absolute error in the first two periods (40ms) of the waveform is marked. It can be seen that the similarity between the reformulated waveform using the first two periods (40ms) of the SCC and the original one is also quite high.…”
Section: The Correlation Analysis Between the Reformulated Scc Wavefo...mentioning
confidence: 99%
See 1 more Smart Citation
“…The correlation coefficient and relative error between the reformulated SCC waveform expressed by Equation ( 21) and the original one by Equation ( 1) are respectively calculated by Equation ( 5) and (6), which are: cxy = 0.999 980 063 830 419, ε = 3.987 194 171 128 92 × 10 −5 The curve of the absolute errors of the reformulated SCC is shown in Figure 13, where the maximum absolute error in the first two periods (40ms) of the waveform is marked. It can be seen that the similarity between the reformulated waveform using the first two periods (40ms) of the SCC and the original one is also quite high.…”
Section: The Correlation Analysis Between the Reformulated Scc Wavefo...mentioning
confidence: 99%
“…for the safe and reliable operation of the systems [1] [2]. In fault recording acquired by the digital devices such as fault recorders or microprocessor-based protection there contained the variation of electrical physical quantities in abnormal or fault states of power systems [3][4] [5], which is applied to performance analysis of devices, fault detection, and protective setting [6] etc. In the fault recording, such as waveforms of currents and voltages, in addition to fundamental frequency components (FFCs) there are still dc, harmonic, and inter-harmonic components [7], etc.…”
Section: Introductionmentioning
confidence: 99%
“…Con el objetivo de describir un valor normal del ancho de banda (ancho del histograma de perfusión miocárdica) para la población estudiada; se calculó un intervalo de referencia del 90% usando la metodología de Wellek y col. 24,25 , así como el paquete estadístico R (Reference intervals) 26 ; lo cual consiste en la eliminación de valores extremos y estimación de los límites del 5 y 95%, en la distribución de datos, como los valores dentro de los cuales se encuentra la normalidad. Se utilizaron los datos de los pacientes sin enfermedad y con características normales, es decir: sin sobrepeso, sin obesidad, exentos de antecedentes de tabaquismo o diabetes, clase funcional NYHA I y II, sin antecedentes cardíacos (infarto agudo de miocardio, cateterismo y/o bypass coronario), ritmo sinusal, ancho del QRS <150 mseg, sin bloqueos de ramas del haz de His y parámetros del SPECT normales (Score isquémico de estrés <3, dilatación isquémica transitoria <1.12 y un ancho de banda <135°).…”
Section: Análisis Estadísticounclassified
“…Fault recording of electrical physical quantities acquired by digital fault recorders and microcomputer protection devices etc. is one of the sources of fault data, which is also used to achieve such functions as equipment performance analysis, disturbance analysis, and power system planning, etc 2 .…”
Section: Introductionmentioning
confidence: 99%