2013
DOI: 10.1120/jacmp.v14i1.4032
|View full text |Cite
|
Sign up to set email alerts
|

Retrospective analysis of linear accelerator output constancy checks using process control techniques

Abstract: Shewhart control charts have previously been suggested as a process control tool for use in routine linear accelerator (linac) output verifications. However, a comprehensive approach to process control has not been investigated for linac output verifications. The purpose of this work is to investigate a comprehensive process control approach to linac output constancy quality assurance (QA). The RBA‐3 dose constancy check was used to verify outputs of photon beams and electron beams delivered by a Varian Clinac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0
2

Year Published

2014
2014
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 37 publications
(35 citation statements)
references
References 22 publications
(25 reference statements)
1
31
0
2
Order By: Relevance
“…The frequency and action level can be modified based on the results of this type of studies along with comprehensive statistical analysis of the type done by Sanghangthum et al 7 .…”
Section: Introductionmentioning
confidence: 99%
“…The frequency and action level can be modified based on the results of this type of studies along with comprehensive statistical analysis of the type done by Sanghangthum et al 7 .…”
Section: Introductionmentioning
confidence: 99%
“…Dosimetric and mechanical QC of a linac is the process of keeping the accuracy of machine functions within suggested tolerance limits. [1,2] Reports and documents for these suggested values have been published by the International Atomic Energy Agency (IAEA), the American Association of Physicists in Medicine (AAPM), the European Society for Therapeutic Radiology and Oncology (ESTRO), and by several other national and international organizations. [3] The main purpose of all these QA programs is to standardize function of the treatment and measurement equipment used in RT facilities, and thus to maximize quality of patient care.…”
Section: Aqa Test Analysis For Cyberknife Robotic Radiosurgery Systemmentioning
confidence: 99%
“…Nevertheless, medical physics departments have a great deal of stored historical data regarding many controlled systems (Sanghangthum et al, 2013b;Gagneur and Ezzell, 2014). In our opinion, these vast data sets can be contrasted against an SPC monitoring system, as we have done here, before starting ambitious blind-prospective SPC experiments.…”
Section: The Use Of Prospective Data In Statistical Process Controlmentioning
confidence: 96%
“…We did not want to neglect this recommendation and so we verified our samples with the Ryan-Joiner test as well and obtained a p>0.100 in all cases. With regard to a lack of normality, one can also work with the exponentially weighted moving average (EWMA) control chart, which is not sensitive to non-normality, although its ability to detect small shifts makes it suitable only when the process under study is well within control (Gérard et al, 2009;Sanghangthum et al, 2013b). Finally, other capability indices have been derived to deal with non-normal data.…”
Section: Data Normalization Capability and Detection Propertiesmentioning
confidence: 98%
See 1 more Smart Citation