2014
DOI: 10.1109/tia.2013.2269895
|View full text |Cite
|
Sign up to set email alerts
|

Retrofitting of Harmonic Power Filters in Onshore Oil Drilling Rigs: Challenges and Solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
2

Year Published

2015
2015
2020
2020

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 25 publications
0
5
0
2
Order By: Relevance
“…Simulation environment has been chosen based on a practical system in oil drilling rigs where several high power drives are connected at a common bus bar and a V THD of 16% and I THD of 18% is present at PCC [14]. For this simulation two 900 kVA nonlinear load, harmonic source-1(compensated load) and harmonic source-2 (uncompensated load) has been considered.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Simulation environment has been chosen based on a practical system in oil drilling rigs where several high power drives are connected at a common bus bar and a V THD of 16% and I THD of 18% is present at PCC [14]. For this simulation two 900 kVA nonlinear load, harmonic source-1(compensated load) and harmonic source-2 (uncompensated load) has been considered.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…This method is applied in this work to extract the harmonics. The system data taken into consideration is based on a practical field data presented in [14] ,where several generators are connected at a common bus bar and it serves to various nonlinear and linear loads. A simplified diagram of the system is presented in Fig.…”
Section: Saf Control Strategymentioning
confidence: 99%
“…Bununla birlikte, özellikle büyük anma güçleri için, yüksek maliyetlidirler [5,6]. Dolayısıyla, pasif filtreler günümüz güç sistemlerinde halen yaygın olarak tercih edilmektedir [7][8][9]. Direnç, bobin ve kondansatör elemanlarından oluşan pasif filtreler, şebekeye bağlantı şekillerine göre, seri ve paralel olarak iki sınıfa ayrılırlar [5,6].…”
Section: öZunclassified
“…Bununla birlikte, özellikle büyük anma güçleri için, yüksek maliyetlidirler [5,6]. Dolayısıyla, pasif filtreler günümüz güç sistemlerinde halen yaygın olarak tercih edilmektedir [7][8][9].…”
Section: Introductionunclassified
“…Non-linear loads are commonly present in industrial facilities, service facilities, office buildings, and even in our homes. They are the source of several Power Quality problems such as harmonics, reactive power, flicker and resonance [4][5]. Therefore, it can be observed an increasing deterioration of the electrical power grid voltage and current waveforms, mainly due to the contamination of the system currents with harmonics of various orders, including inter-harmonics [6].…”
Section: Introductionmentioning
confidence: 99%