2007
DOI: 10.1016/j.cep.2006.03.018
|View full text |Cite
|
Sign up to set email alerts
|

Retrofitting for DME process by energy-flow framework diagram

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…Distillation columns were already available in the analyzed plant and their dimensions and characteristics coincided with the planned ones. The objective function-annual profit (Equation (35)) that represents the difference between all incomes and all expenses on an annual basis, was chosen as the optimization criterion. It is formed under conditions of continuous and discrete variables by equations (Equation (36))-(Equation (40)).…”
Section: Mathematical Modellingmentioning
confidence: 99%
See 1 more Smart Citation
“…Distillation columns were already available in the analyzed plant and their dimensions and characteristics coincided with the planned ones. The objective function-annual profit (Equation (35)) that represents the difference between all incomes and all expenses on an annual basis, was chosen as the optimization criterion. It is formed under conditions of continuous and discrete variables by equations (Equation (36))-(Equation (40)).…”
Section: Mathematical Modellingmentioning
confidence: 99%
“…The alternative process scheme F (Appendix VII) represents a synthesis process a pressure of 50 bar and a temperature of 270˚C. Mentioned process scheme was further examined by the authors [35].…”
Section: Direct Synthesis Of Dme and A Review Of The Process Alternatmentioning
confidence: 99%
“…A feature of both graphical analyses is that it is easy to show the input and output relations of the energy balance and give a quantitative description of the energy flow as well as a complete concept of the system energy flow structure. Besides, based on these two graphical analysis methods, Zheng proposed another graphic tool named EFD (Energy-flow Framework Diagram) for the exergy analysis . EFD describes the utilization of energy based on the concept of node and flow.…”
Section: Introductionmentioning
confidence: 99%
“…Besides, based on these two graphical analysis methods, Zheng proposed another graphic tool named EFD (Energy-flow Framework Diagram) for the exergy analysis. 18 EFD describes the utilization of energy based on the concept of node and flow. In addition, it describes the energy transfer and exergy loss between internal systems and utilities.…”
Section: Introductionmentioning
confidence: 99%