2020
DOI: 10.3390/ma13143193
|View full text |Cite
|
Sign up to set email alerts
|

Retentive Force of Glass-Ceramic Soldered Customized Zirconia Abutment Copings with Prefabricated Titanium Bases

Abstract: Two-piece abutments consisting of customized zirconia abutment copings and prefabricated titanium bases are popular due to their biological and esthetic advantages. Glass–ceramic solder (GS) is an alternative biocompatible connective agent. This in vitro study evaluated the retentive force of GS in comparison to classical resin composite cements (RC) after artificial aging and autoclaving. Ninety specimens consisting of prefabricated titanium bases and zirconia abutment copings were fabricated. The two parts o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(1 citation statement)
references
References 33 publications
0
1
0
Order By: Relevance
“…The specimens were then aged using a thermocycling machine made speci cally for the purpose (Dental biomaterials Department, Alexandria University, Egypt) for 2000 cycles, or 3 months of clinical service, in water baths between 5 and 55 degrees Celsius with dwell times of 1 minute in each bath and relaxation periods of 30 seconds in air between the 2 baths. 20 The specimens were subsequently secured to a specially designed cyclic loading apparatus (Dental biomaterials Department, Alexandria University, Egypt) and loaded with an average functional masticatory force of 50 N over a mean of 120 000 cycles. 21 After aging, the stereomicroscope was used again to evaluate the effect of thermocycling and cyclic loading on the marginal adaptation for both groups.…”
Section: Methodsmentioning
confidence: 99%
“…The specimens were then aged using a thermocycling machine made speci cally for the purpose (Dental biomaterials Department, Alexandria University, Egypt) for 2000 cycles, or 3 months of clinical service, in water baths between 5 and 55 degrees Celsius with dwell times of 1 minute in each bath and relaxation periods of 30 seconds in air between the 2 baths. 20 The specimens were subsequently secured to a specially designed cyclic loading apparatus (Dental biomaterials Department, Alexandria University, Egypt) and loaded with an average functional masticatory force of 50 N over a mean of 120 000 cycles. 21 After aging, the stereomicroscope was used again to evaluate the effect of thermocycling and cyclic loading on the marginal adaptation for both groups.…”
Section: Methodsmentioning
confidence: 99%