2008
DOI: 10.1016/j.jchromb.2008.04.042
|View full text |Cite
|
Sign up to set email alerts
|

Retention index thresholds for compound matching in GC–MS metabolite profiling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
133
1

Year Published

2009
2009
2018
2018

Publication Types

Select...
7
3

Relationship

3
7

Authors

Journals

citations
Cited by 161 publications
(135 citation statements)
references
References 35 publications
1
133
1
Order By: Relevance
“…de/; Kopka et al, 2005;Schauer et al, 2005;Hummel et al, 2010), dated 3/15/2011. At least four matching masses were required with a minimum match value of 750 and a maximum retention index deviation of 1.0 for the positive annotation of an analyte (Strehmel et al, 2008). From the annotated analytes, a data profile was calculated, where the intensities of each analyte were scaled to 100 over the different samples.…”
Section: Gc-ms: Polar Metabolitesmentioning
confidence: 99%
“…de/; Kopka et al, 2005;Schauer et al, 2005;Hummel et al, 2010), dated 3/15/2011. At least four matching masses were required with a minimum match value of 750 and a maximum retention index deviation of 1.0 for the positive annotation of an analyte (Strehmel et al, 2008). From the annotated analytes, a data profile was calculated, where the intensities of each analyte were scaled to 100 over the different samples.…”
Section: Gc-ms: Polar Metabolitesmentioning
confidence: 99%
“…Metabolites were annotated manually using the Target Finder function in the TagFinder software using the Golm Metabolome Database (Kopka et al, 2005) (http://gmd.mpimp-golm.mpg.de). Criteria for manual metabolite identification were the presence of at least four specific mass fragments per compound, a match value >750, and a retention index deviation <1.0% (Strehmel et al, 2008).…”
Section: Measurements Of Metabolites By Gc-msmentioning
confidence: 99%
“…Compounds were identified comparing RIs and mass spectra with the UPSC-SMC in-house database and with the public Golm Metabolome Database of the Max Planck Institute. For comparison with the Golm Metabolome Database, RIs measured on the 5% phenyl-95% dimethylpolysiloxane capillary column VAR5 (Golm Metabolome Database) were transferred to the DB-5 (10m) system of the UPSC-SMC (Strehmel et al, 2008;Hummel et al, 2010). Samples were normalized on the unit variance and no centering (UVN) scores of integrated areas for the internal standards (methyl stearate and salicylic acid-D4).…”
Section: Data Processing and Identificationmentioning
confidence: 99%