2009
DOI: 10.1007/s00784-009-0315-z
|View full text |Cite
|
Sign up to set email alerts
|

Retention force measurement of telescopic crowns

Abstract: This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were anal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
24
0
1

Year Published

2011
2011
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(30 citation statements)
references
References 6 publications
4
24
0
1
Order By: Relevance
“…This phenomenon explains the strain of the surface of the crown depends on the malleability of materials use. This phenomenon is characteristic especially for crowns made of gold alloys, where the observed initial decrease in the value of the retention force is momentarily stabilized until another decline in value and eventual complete loss of retention [1,31,32,35,36]. In this study the initial phase in all groups was in the range of 0-2500 cycles, followed by a period of relative stabilization of the value of the retention force in the range of 30000 cycles.…”
Section: Discussionmentioning
confidence: 56%
See 3 more Smart Citations
“…This phenomenon explains the strain of the surface of the crown depends on the malleability of materials use. This phenomenon is characteristic especially for crowns made of gold alloys, where the observed initial decrease in the value of the retention force is momentarily stabilized until another decline in value and eventual complete loss of retention [1,31,32,35,36]. In this study the initial phase in all groups was in the range of 0-2500 cycles, followed by a period of relative stabilization of the value of the retention force in the range of 30000 cycles.…”
Section: Discussionmentioning
confidence: 56%
“…The retention value obtained in the study of a single support tooth cannot refer to the final retention of the prosthesis based on it, especially if there are other support teeth provided with telescopic crowns. Retention of the prosthesis based on more than one telescopic crown is not a simple sum of the individual pillars and the retention does not correlate with their number [35].…”
Section: Discussionmentioning
confidence: 97%
See 2 more Smart Citations
“…After initial titles and abstracts screening , 701 irrelevant articles were excluded and a total of 41 articles were selected for full-text screening, 2 additional articles were found through hand searching [4,5] . After full text screening, 15 articles [4][5][6][7][8][9][10][11][12][13][14][15][16][17][18] were included in the present analysis.…”
Section: Results:-mentioning
confidence: 99%