2011
DOI: 10.1016/j.ces.2011.03.054
|View full text |Cite
|
Sign up to set email alerts
|

Restoration of particle size distributions from fiber-optical in-line measurements in fluidized bed processes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 35 publications
0
10
0
Order By: Relevance
“…In another study the characteristics of the chord length were observed and it was pointed out that a CLD does not clearly reflect the underlying particle size distribution (PSD) [28]. Therefore, a mathematical approach to transform the SFV-CLD into a PSD was performed by Fischer et al [29]. The individual values detected by the SFV probe are written continuously into the flexible storage system.…”
Section: Introductionmentioning
confidence: 98%
See 1 more Smart Citation
“…In another study the characteristics of the chord length were observed and it was pointed out that a CLD does not clearly reflect the underlying particle size distribution (PSD) [28]. Therefore, a mathematical approach to transform the SFV-CLD into a PSD was performed by Fischer et al [29]. The individual values detected by the SFV probe are written continuously into the flexible storage system.…”
Section: Introductionmentioning
confidence: 98%
“…The individual values detected by the SFV probe are written continuously into the flexible storage system. It was mentioned in the literature that the selected size of this particle ring buffer influences the latency of the probe and observations on the optimal buffer size were made in preliminary investigations [29].…”
Section: Introductionmentioning
confidence: 99%
“…6) suggesting that used pellets had spherical shape and off-line measurements were a good approximation of the actual particle size. On the other hand, SFT characterises particle by measuring CL perpendicular to the direction of the measuring beam (Fischer et al, 2011). Consequently, SFT measures actual pellet diameter only in case when chord is passing through the centre Table 6 Comparison of SFT and SA particle size distribution of the third batch.…”
Section: In-line Particle Size Measurement With the Sft Probementioning
confidence: 99%
“…Location of the NIR within the sensor is a critical parameter in the measurements and it is useless for monitoring of bed hydrodynamic behavior or assuring of spatial resolution [14] . The moisture content affects the measurement in monitoring the particle size, [71] and it gives only statistical characteristics without giving actual information about particle size [72] . While, it is worth mentioning that the NIR imaging system (hyperspectral imaging spectrometer) has been developed within the last few years with the ability to simultaneously record spectral and spatial information of particles.…”
Section: Nir Spectroscopymentioning
confidence: 99%