1987
DOI: 10.1113/jphysiol.1987.sp016621
|View full text |Cite
|
Sign up to set email alerts
|

Responses in small hand muscles from magnetic stimulation of the human brain.

Abstract: SUMMARY1. The magnetic field generated by a brief current in a 9 cm diameter flat circular coil varies rapidly with time and when applied over the human scalp it is capable of exciting motor structures subserving the small hand muscles. With a peak magnetic field at the centre of the coil of 09-1-6 Tesla, single scalp stimuli produced twitches in the right abductor digiti minimi (a.d.m.), first dorsal interosseous (f.d.i.) and adductor pollicis muscles. Compound muscle action potentials (c.m.a.p.s) and single … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

12
290
3
26

Year Published

1989
1989
2015
2015

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 686 publications
(331 citation statements)
references
References 29 publications
(35 reference statements)
12
290
3
26
Order By: Relevance
“…Variance in EMG power can typically explain part of the variance in MEP amplitude (Hess et al, 1987). The observed relation between MEP amplitude and pre-TMS EMG phase might therefore be confounded by a potential relation between pre-TMS EMG phase and pre-TMS EMG power.…”
Section: Resultsmentioning
confidence: 99%
“…Variance in EMG power can typically explain part of the variance in MEP amplitude (Hess et al, 1987). The observed relation between MEP amplitude and pre-TMS EMG phase might therefore be confounded by a potential relation between pre-TMS EMG phase and pre-TMS EMG power.…”
Section: Resultsmentioning
confidence: 99%
“…Recordings were carried out through surface electrodes at rest and during voluntary contraction of the ABP muscle, a condition in which the probability of a TMS-linked corticospinal neuronal discharge with consequent muscular activation is much higher than during target muscle relaxation (Hess et al, 1987;Rossini et al, 1999). Bandpass filtering was 20 Hz-2 kHz, with amplifiers at a maximal gain.…”
Section: Neurophysiological Measurementsmentioning
confidence: 99%
“…3b). This represents an important difference from limb muscles, where it is generally admitted that a voluntary contraction amounting to 10-20% of maximal strength is sufficient to maximize the effects of facilitation [33]. Only two subjects (Nos.…”
Section: Effects Of An Underlying Contraction On the Diaphragmatic Rementioning
confidence: 99%