2011
DOI: 10.1118/1.3578613
|View full text |Cite
|
Sign up to set email alerts
|

Response to “Comment on ‘A planning quality evaluation tool for prostate adaptive IMRT based on machine learning’ ” [Med. Phys. 38, 719 (2011)]

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…The dose deposited in an OAR voxel depends not only on its distance to PTV surface, but also on treatment beam orientations. 3,11,12 Two OAR voxels with the same distance to the PTV may have large difference in received dose, simply because one is in the beam's direction and the other is outside the radiation field. As examples, a prostate and a HN plan with calculated dose distributions are shown in Figs.…”
Section: Iib Factors That Affect Oar Dosesmentioning
confidence: 99%
“…The dose deposited in an OAR voxel depends not only on its distance to PTV surface, but also on treatment beam orientations. 3,11,12 Two OAR voxels with the same distance to the PTV may have large difference in received dose, simply because one is in the beam's direction and the other is outside the radiation field. As examples, a prostate and a HN plan with calculated dose distributions are shown in Figs.…”
Section: Iib Factors That Affect Oar Dosesmentioning
confidence: 99%
“…Although the concept of PTsymmetric quantum mechanics, as a fundamental theory, is still under a heated debate [27], it has been explored in optics and electronics by means of interleaving balanced gain-and-loss regions. Several interesting physical features have been explored, such as power oscillations [28], unidirectional invisibility [29][30][31][32], the reconfigurable Talbot effect [33], and coherent perfect laser absorbers [34,35]. Moreover, in the nonlinear domain, PT symmetry has been used to realize potential optical isolators and circulators [36][37][38][39][40].…”
Section: Introductionmentioning
confidence: 99%
“…However, one concern regarding the DTH and OVH is that their simplicity may lead to inaccurate presentation of the interpatient variations in anatomical features, which may have an impact on the organ dose deposition [ 5 , 6 ], especially for complex tumour volumes in close proximity to critical structures such as those observed in nasopharyngeal carcinomas (NPCs). The dose deposited in an OAR voxel depends not only on its distance from the PTV surface but also on the treatment beam orientation [ 5 , 7 , 8 ].…”
Section: Introductionmentioning
confidence: 99%