Abstract: BackgroundOscillometry has been employed widely as a non-invasive and standardized measurement of respiratory function in children and adults; however, limited information is available on infants.AimsTo establish the within-session variability of respiratory impedance (Zrs), to characterize the degree and profile of intra-breath changes in Zrs and to assess their impact on conventional oscillometry in newborns.Methods109 healthy newborns were enrolled in the study conducted in the first 5 postpartum days durin… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 39 publications
0
4
0
Order By: Relevance
“…Currently, no oscillometry reference equations exist for African populations, despite the high burden of respiratory disease in the region. Additionally, normative data on the novel intra-breath oscillometry measures are scant [ 8 ] and are not available for paediatric populations beyond infancy [ 9 , 36 ]. Recent technical standards for oscillometry equipment and testing, developed by a European Respiratory Society (ERS) task force have highlighted the lack of appropriate paediatric reference standards, especially for underrepresented populations [ 37 ].…”
Section: Introductionmentioning
confidence: 99%
“…Currently, no oscillometry reference equations exist for African populations, despite the high burden of respiratory disease in the region. Additionally, normative data on the novel intra-breath oscillometry measures are scant [ 8 ] and are not available for paediatric populations beyond infancy [ 9 , 36 ]. Recent technical standards for oscillometry equipment and testing, developed by a European Respiratory Society (ERS) task force have highlighted the lack of appropriate paediatric reference standards, especially for underrepresented populations [ 37 ].…”
Section: Introductionmentioning
confidence: 99%
“…A minimum of 20 regular breathing periods with no artefacts were collected for each infant for intrabreath analysis, and the recording was repeated if necessary. Details of equipment, signal processing and Zrs analysis are previously described 14. Zrs was characterised by resistance (Rrs) and reactance (Xrs) at end expiration (R eE and X eE , respectively) and at end inspiration (R eI and X eI , respectively).…”
Section: Methodsmentioning
confidence: 99%
“…Details of equipment, signal processing and Zrs analysis are previously described. 14 Zrs was characterised by resistance (Rrs) and reactance (Xrs) at end expiration (R eE and X eE , respectively) and at end inspiration (R eI and X eI , respectively). The corresponding tidal changes in Zrs were calculated as ΔR=R eE R eI and ΔX=X eE X eI as well as their values normalised by tidal volume (V T ).…”
Section: Methodsmentioning
confidence: 99%
“…However, intra-breath measurement of respiratory mechanics has been proven to help identify such phenomena as airway obstruction, expiratory flow limitation, and mechanical heterogeneity in both children and adults (111,(201)(202)(203)(204). In addition, improved ability of intrabreath oscillometry to detect changes in airway tone in children compared to classic oscillometry as well as to predict the risk of respiratory infection in early life has been shown in previous studies (110,205,206). At the time the study was instituted, preliminary intra-breath analysis was performed.…”
Section: Univariable Multivariablementioning
confidence: 97%