2022
DOI: 10.1002/mrm.29183
|View full text |Cite
|
Sign up to set email alerts
|

Respiration induced B1+ changes and their impact on universal and tailored 3D kT‐point parallel transmission pulses for 7T cardiac imaging

Abstract: This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(15 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…5 Tailored pTx in the human body can be challenging and time-consuming, particularly for the excitation of different respiration states or multiple resonance frequencies, due to increased computational demands and potential motion between B + 1 -mapping and pTx data acquisition. 8,12,30 The proposed broadband UP BB provides a robust alternative to TP BB for a 1307 Hz frequency range, including all six primary fat and the water peak, acceptable FA homogeneity. On average, the broadband UP approach saves roughly 10-15 min of adjustment times for B + 1 -acquisition (3:35 min), non-Cartesian reconstruction (1 min), manual ROI drawing (3 min), and pulse design and quality checks (up to 5 min).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…5 Tailored pTx in the human body can be challenging and time-consuming, particularly for the excitation of different respiration states or multiple resonance frequencies, due to increased computational demands and potential motion between B + 1 -mapping and pTx data acquisition. 8,12,30 The proposed broadband UP BB provides a robust alternative to TP BB for a 1307 Hz frequency range, including all six primary fat and the water peak, acceptable FA homogeneity. On average, the broadband UP approach saves roughly 10-15 min of adjustment times for B + 1 -acquisition (3:35 min), non-Cartesian reconstruction (1 min), manual ROI drawing (3 min), and pulse design and quality checks (up to 5 min).…”
Section: Discussionmentioning
confidence: 99%
“…The safety limits were meticulously executed following established protocols and consistent with previous studies conducted in this field. 5,11,12,30,31,38…”
Section: Volunteer Information and Mr Scanner Hardwarementioning
confidence: 99%
See 2 more Smart Citations
“…Another patient‐friendly option would be to add respiratory binning, 69 allowing free breathing and therefore B1+$$ {\mathrm{B}}_1^{+} $$ mapping flexibility. Calculating respiration‐robust k T ‐points, possibly universal, pulses based on these respiration‐resolved B1+$$ {\mathrm{B}}_1^{+} $$ maps as in Aigner et al 70 would make the proposed method suitable for numerous other abdominal applications such as Dixon, 71 dynamic contrast enhancement, 72 and 4D Flow 73 …”
Section: Discussionmentioning
confidence: 99%