2019
DOI: 10.1109/tie.2018.2808904
|View full text |Cite
|
Sign up to set email alerts
|

Resonant Wireless Charging System Design for 110-kV High-Voltage Transmission Line Monitoring Equipment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 95 publications
(26 citation statements)
references
References 21 publications
0
26
0
Order By: Relevance
“…Equations (4) and (5) show that the variation of the equivalent load resistance R L influences I 1 and the power transmitted to the load is equal to the power consumed by the real part of the impedance Z p . Therefore Z p has a link with the active power P 0 of the circuit.…”
Section: Mutual Inductance Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…Equations (4) and (5) show that the variation of the equivalent load resistance R L influences I 1 and the power transmitted to the load is equal to the power consumed by the real part of the impedance Z p . Therefore Z p has a link with the active power P 0 of the circuit.…”
Section: Mutual Inductance Modelmentioning
confidence: 99%
“…Wireless power transfer (WPT) technology has become one of the critical technology applications in the fields of transportation [1,2], underwater power supplies [3], biomedical implants [4], highvoltage transmission [5] and electric vehicles (EVs) [6,7]. In particular, the electric bike (EB) is in common use in many regions including China and Europe [8].…”
Section: Introductionmentioning
confidence: 99%
“…The diameter and weight of coupling coils should be decreased to reduce the impact on the insulators. The 24-turn and 20 cm radius helix windings are adopted in the desired WPT system to balance the size and capacity [14]. The transmission distance of desired WPT systems is three times longer than the diameter of coils, and the coupling between transmitting and receiving coils is extremely loose.…”
Section: System Overviewmentioning
confidence: 99%
“…are all known, the cross-sectional area of the core can then be calculated according to (13). Parameters of the core are defined as follows: the crosssectional perimeter is L 1 , the average length of magnetic circuit is L m , the cross-sectional width is b, the cross-sectional internal radius is r. On the basis, the detailed relationship among these parameters can be written as…”
Section: Analysis and Design Of Core And Coil Turnsmentioning
confidence: 99%
“…At present, more and more researchers begin to pay attention to the application of WPT technology to the energy supply of the online monitoring device for HVPLs, which solved some theoretical and practical problems [13][14][15]. Based on the research results, this study focuses on the optimisation design of online energy harvesting device and the WPT system with double relay coils by taking both HVPL insulation distance and wireless power supply efficiency into account.…”
Section: Introductionmentioning
confidence: 99%