1993
DOI: 10.1016/0003-2670(93)80467-y
|View full text |Cite
|
Sign up to set email alerts
|

Resonant frequency of a piezoelectric quartz crystal in contact with solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
2

Year Published

1994
1994
2020
2020

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 22 publications
0
4
0
2
Order By: Relevance
“…Many studies have been performed to overcome the inherent disadvantages of the conventional impedance-based measurement system. 14,35,[37][38][39][40][41][42][43][44] They mainly focused on solving the issues like an efficient extraction of the BVD model parameters, fast data acquisition, lower cost, and miniaturization of the system.…”
Section: Impedance-based Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…Many studies have been performed to overcome the inherent disadvantages of the conventional impedance-based measurement system. 14,35,[37][38][39][40][41][42][43][44] They mainly focused on solving the issues like an efficient extraction of the BVD model parameters, fast data acquisition, lower cost, and miniaturization of the system.…”
Section: Impedance-based Measurementmentioning
confidence: 99%
“…Some interesting approaches have been studied by implementing a voltage division or impedance divider network. 14,38,43 They adopted a voltage division network by placing a capacitor between a frequency sweeping unit and a resonance sensor. The voltage division technique is illustrated in Fig.…”
Section: Impedance-based Measurementmentioning
confidence: 99%
“…However, instead of being designed for recovering the information associated with the conductance and susceptance spectra of the sensor around resonance, which is more involved in terms of electronic design, they acquire the representative magnitudes of voltages associated with a “voltage transfer function” in which the impedance of the sensor takes part. Then, the impedance of the sensor is replaced by an appropriate model whose parameters are fitted to the experimental voltage transfer function acquired [ 56 , 57 ].…”
Section: Systems For Sensor Parameter Characterizationmentioning
confidence: 99%
“…Тем не менее,' следует отметить, что в каждом конкретном случае работы над созданием сенсоров для анализа в жидкостях на основе грави метрического метода необходимы либо соответствующая модификация и подстройка схемы генератора, либо применение других подходов измерения характеристик пьезокристаллов [7]. Одним из таких подходов является резонансный метод.…”
Section: рис 4 схемы кварцевых генераторов позволяющие работать в unclassified