2022
DOI: 10.1016/j.electacta.2022.140886
|View full text |Cite
|
Sign up to set email alerts
|

Resolution increase of ion-selective electrodes response by using a reversed amperometric setup

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…The application of ion-selective electrode in chemical analysis and detection by Wang Yalin et al has also shown high applicability, gradually becoming a mainstream analysis technology in the field of chemical analysis [10].Based on the discovery of several new mechanisms in ionic interface reactions, Li Hang et al established an ion-selective electrode method based on the multi-parameter joint analysis principle of soil particle surface properties, realizing the joint determination of soil surface property parameters [11].KaliszJustyna used AgCl electrode as working electrode, ion-selective electrode as reference electrode, and "reverse" amperage setting to significantly amplify the potential response of ISE [12].Using this method, the linear dependence of the current on the concentration of the model analyte (potassium and calcium ions) can be recorded even in a narrow concentration range (e.g., 1.34 to 1.10mA for calcium ions), and the change in the open-circuit potential recorded there is negligible. KhoshnoodRaziehSanavi prepared an aluminum ion selective electrode, which is used for quantitative analysis of aluminum ions in the presence of various cations such as alkaline ions, neutral ions and heavy metal ions [13].According to the results, the aluminum ion nanocomposite carbon slurry sensor shows good selectivity in the presence of a few metal ions, and the response of the sensor is independent of pH value, the range is 24, and the response time is less than 5s.…”
Section: Quotementioning
confidence: 99%
“…The application of ion-selective electrode in chemical analysis and detection by Wang Yalin et al has also shown high applicability, gradually becoming a mainstream analysis technology in the field of chemical analysis [10].Based on the discovery of several new mechanisms in ionic interface reactions, Li Hang et al established an ion-selective electrode method based on the multi-parameter joint analysis principle of soil particle surface properties, realizing the joint determination of soil surface property parameters [11].KaliszJustyna used AgCl electrode as working electrode, ion-selective electrode as reference electrode, and "reverse" amperage setting to significantly amplify the potential response of ISE [12].Using this method, the linear dependence of the current on the concentration of the model analyte (potassium and calcium ions) can be recorded even in a narrow concentration range (e.g., 1.34 to 1.10mA for calcium ions), and the change in the open-circuit potential recorded there is negligible. KhoshnoodRaziehSanavi prepared an aluminum ion selective electrode, which is used for quantitative analysis of aluminum ions in the presence of various cations such as alkaline ions, neutral ions and heavy metal ions [13].According to the results, the aluminum ion nanocomposite carbon slurry sensor shows good selectivity in the presence of a few metal ions, and the response of the sensor is independent of pH value, the range is 24, and the response time is less than 5s.…”
Section: Quotementioning
confidence: 99%
“…Practical applications of ion-selective electrodes (ISEs) with membranes containing ionophores usually involve recordings of the EMF: a zero-current potentiometric signal (ISE potential) measured against a suitable reference electrode (RE). However, in recent years, ISEs have been increasingly used in non-zero-current modes: voltammetry [1][2][3][4][5][6][7] and chronoamperometry/coulometry [8][9][10][11][12][13][14][15][16][17][18]. A voltammetric analysis with ISEs allows for simultaneous measurements of the concentrations (rigorous activities) of several ions in a sample, using only one electrode [1][2][3][4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…In chronoamperometric measurements, the currents flowing through membranes (and therefore across membrane/solution interfaces) are typically low: 10 −9 -10 −7 A. However, sometimes they may achieve 10 −4 A, especially in the reversed amperometric setup [18]. Thus, ISEs may be polarized during measurements whereas the interpretation of the results assumes their Nernstian response to activities of ions in solutions.…”
Section: Introductionmentioning
confidence: 99%
“…However, this improvement required multiple ISEs (30 for chloride and 10 for both other ions) to be connected. More recently, amperometry with an inverted electrode configuration was successfully applied to increase the sensitivity of ISEs . The ISE was used as a reference electrode (RE), while an Ag/AgCl element was treated as a nonpolarizable working electrode (WE).…”
mentioning
confidence: 99%
“…More recently, amperometry with an inverted electrode configuration was successfully applied to increase the sensitivity of ISEs. 13 The ISE was used as a reference electrode (RE), while an Ag/AgCl element was treated as a nonpolarizable working electrode (WE). This method gave a linear dependence on concentration within a limited concentration range and high-resolution pH sensing was also achieved.…”
mentioning
confidence: 99%