2020
DOI: 10.3390/s20195557
|View full text |Cite
|
Sign up to set email alerts
|

Resolution Improvement of Light Field Imaging via a Nematic Liquid Crystal Microlens with Added Multi-Walled Carbon Nanotubes

Abstract: A relatively simple method to improve the image resolution of light field based on a liquid crystal (LC) microlens doped with multi-walled carbon nanotubes (MWCNTs) was developed and evaluated. As the nanoparticles were doped in LC, its electro-optical features could enhance, leading to a short response time compared to the pure LC microlens. With the maximum use of the proposed LC microlens, a method combining aperiodicity extraction and weighted average algorithm was adopted to realize the high-resolution li… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 36 publications
0
3
0
Order By: Relevance
“…The first group adopted the regular glass type MLA without LC-MLA (glass MLA-type 150-5C from Thorlabs Co). The second group adopted LC-MLA without depolarization algorithm (the applied voltage at 2 V rms ) [33]. The third group adopted LC-MLA with a depolarization algorithm (the lens state is the applied voltage at 2 V rms , the non-lens state is without applied voltage).…”
Section: Resultsmentioning
confidence: 99%
“…The first group adopted the regular glass type MLA without LC-MLA (glass MLA-type 150-5C from Thorlabs Co). The second group adopted LC-MLA without depolarization algorithm (the applied voltage at 2 V rms ) [33]. The third group adopted LC-MLA with a depolarization algorithm (the lens state is the applied voltage at 2 V rms , the non-lens state is without applied voltage).…”
Section: Resultsmentioning
confidence: 99%
“…Finally, an aperiodic algorithm extracts sub-views for each single wavelength. [41] The number of sub-views is 24 Â 24. The decoupling process is in detail, as shown in Figure 1d.…”
Section: Theory and Fabricationmentioning
confidence: 99%
“…The diagnostic method, bioimaging, is connected with the penetration of drugs and diagnostic agents into tissues and cells and the sensitivity of detection. Bioimaging is controlled by biodegradability, biocompatibility, specificity, and applicability for carbon nanotubes [68][69][70][71][72][73][74][75][76][77][78][79][80][81], graphene [82][83][84][85][86][87][88][89][90][91][92][93][94], fullerenes [95], and dots [96].…”
Section: Introductionmentioning
confidence: 99%