2020
DOI: 10.1103/physrevb.101.035425
|View full text |Cite
|
Sign up to set email alerts
|

Resistively detected NMR in a triple-gate quantum point contact: Magnetic field dependence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 33 publications
0
11
0
Order By: Relevance
“…The electron mobility of the GaAs quantum well, on which the QPCs are fabricated, determines a broadening of the spin‐resolved Landau‐level as shown in Figure 1c so that the minimum magnetic field necessary for the RDNMR detection increases with decreasing the mobility. [ 11 ] Typical RDNMR signals obtained for high‐mobility (μ=1.47×106 cm 2 V −1 s −1 at electron density of 1.8×1011 cm −2 ) and low‐mobility (μ=2.8×105 cm 2 V −1 s −1 at electron density of 1.8×1011 cm −2 ) QPCs are shown in Figure 1d,e, respectively. They are obtained by setting νnormalb=2 and νqpc slightly less than 1, corresponding to a strong tunneling regime discussed later.…”
Section: Basic Of Rdnmr In a Qpcmentioning
confidence: 99%
See 4 more Smart Citations
“…The electron mobility of the GaAs quantum well, on which the QPCs are fabricated, determines a broadening of the spin‐resolved Landau‐level as shown in Figure 1c so that the minimum magnetic field necessary for the RDNMR detection increases with decreasing the mobility. [ 11 ] Typical RDNMR signals obtained for high‐mobility (μ=1.47×106 cm 2 V −1 s −1 at electron density of 1.8×1011 cm −2 ) and low‐mobility (μ=2.8×105 cm 2 V −1 s −1 at electron density of 1.8×1011 cm −2 ) QPCs are shown in Figure 1d,e, respectively. They are obtained by setting νnormalb=2 and νqpc slightly less than 1, corresponding to a strong tunneling regime discussed later.…”
Section: Basic Of Rdnmr In a Qpcmentioning
confidence: 99%
“…For the high‐mobility QPCs, we could clearly observe the RDNMR signal down to B=1.25 T. For the low‐mobility QPCs, successful observation of the signal is limited to B>3 T. However, all signals reflect the Larmor frequency of 75 As as shown in Figure 1f and, more importantly, both lineshape and broadening showed the same tendency, independent of the mobility. [ 11 ] It means that we can see intrinsic characteristics of the RDNMR signals even for the low‐mobility QPC device when we set the magnetic field high enough so that the up and down spin edge channels are well resolved.…”
Section: Basic Of Rdnmr In a Qpcmentioning
confidence: 99%
See 3 more Smart Citations