2011
DOI: 10.1590/s2176-94512011000600011
|View full text |Cite
|
Sign up to set email alerts
|

Resistência ao cisalhamento da colagem dos compósitos Concise e Transbond XT com e sem agente de união

Abstract: Objectives: The aim of this study was to evaluate the shear bond strength of brackets and the adhesive remnant index (ARI) of Concise and Transbond XT composites with and without the use of a bonding agent. Methods: The sample consisted of 60 bovine incisors divided into four groups (n=15). All teeth were subjected to prophylaxis with pumice and enamel etching with phosphoric acid at 37%. In Groups 1 and 2 brackets were bonded with Concise composite with and without application of enamel bond resin, respective… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 20 publications
(27 reference statements)
0
7
0
Order By: Relevance
“…In a comparison of other no-primer orthodontic adhesives, Heliosit composite and Ortho Cem composite were evaluated by Scribante et al 18 The omission of a bonding agent may simplify the clinical procedure, decrease chair time, minimise the risk of moisture contamination, and lower the costs of the bonding process. 9 A comparison of Transbond XT with and without its primer revealed no significant difference in SBS, which indicates that the absence of a priming agent may not compromise the SBS. These findings are consistent with those of Neves et al, 9 Nandhra et al, 13 Shahabi et al, 14 and Rai et al 21 but disagree with the results of Pulido et al, 22 who believed that the application of a primer increases bracket bond strength.…”
Section: Discussionmentioning
confidence: 91%
See 4 more Smart Citations
“…In a comparison of other no-primer orthodontic adhesives, Heliosit composite and Ortho Cem composite were evaluated by Scribante et al 18 The omission of a bonding agent may simplify the clinical procedure, decrease chair time, minimise the risk of moisture contamination, and lower the costs of the bonding process. 9 A comparison of Transbond XT with and without its primer revealed no significant difference in SBS, which indicates that the absence of a priming agent may not compromise the SBS. These findings are consistent with those of Neves et al, 9 Nandhra et al, 13 Shahabi et al, 14 and Rai et al 21 but disagree with the results of Pulido et al, 22 who believed that the application of a primer increases bracket bond strength.…”
Section: Discussionmentioning
confidence: 91%
“…9 A comparison of Transbond XT with and without its primer revealed no significant difference in SBS, which indicates that the absence of a priming agent may not compromise the SBS. These findings are consistent with those of Neves et al, 9 Nandhra et al, 13 Shahabi et al, 14 and Rai et al 21 but disagree with the results of Pulido et al, 22 who believed that the application of a primer increases bracket bond strength.…”
Section: Discussionmentioning
confidence: 91%
See 3 more Smart Citations