2006
DOI: 10.1016/j.jim.2006.02.011
|View full text |Cite
|
Sign up to set email alerts
|

Resin-based micropipette tip for immunochromatographic assays in urine samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0

Year Published

2006
2006
2018
2018

Publication Types

Select...
9

Relationship

3
6

Authors

Journals

citations
Cited by 25 publications
(23 citation statements)
references
References 18 publications
1
22
0
Order By: Relevance
“…This is because when the positive serum was diluted to 1/50, the test line of the larger sized group (upper picture) shows a little red color but the smaller sized group (lower picture) does not. This result is coincident to Teruko Yuhi's work 26 and another literature survey. 27 …”
Section: Comparison Of the Real Sample Testsupporting
confidence: 88%
“…This is because when the positive serum was diluted to 1/50, the test line of the larger sized group (upper picture) shows a little red color but the smaller sized group (lower picture) does not. This result is coincident to Teruko Yuhi's work 26 and another literature survey. 27 …”
Section: Comparison Of the Real Sample Testsupporting
confidence: 88%
“…The lower detection sensitivity in IgG/HSA-depleted samples compared to IgG-depleted samples could in part be due to the role that HSA plays in blocking non-specific adsorption. 20 The absence of HSA (depleted successfully to < 3% 2 and in this study), could have increased non-specific adsorption, thus reducing the potential "optimal" sensitivity of the assay. This highlights the need for detailed studies on high-abundant protein depletion and their individual impact on downstream assays and their applications.…”
Section: Application Of Depletion Protocol To Detection Of Prostate Smentioning
confidence: 76%
“…An immunochromatographic SPR test has been reported for the determination of hCG, which is based on the immobilization of primary antibodies in a thin zone of the chromatographic support, in which the analyte is accumulated, and the conjugation of the secondary antibodies with AuNPs [63]. Other similar immunochromatographic tests for PSA and hCG determination involve the measurement of the intense red color owing to the accumulation of the AuNPs [64][65][66].…”
Section: Sandwich Assaysmentioning
confidence: 99%
“…In some instances, these NPs are only used as nanoscaffolds to improve the immobilization of the antibodies [19,20,84], although other methods involve the measurement of a property of the AuNPs, which is correlated with the analyte concentration, such as SPR [63], light scattering [48,49] and color intensity image [64][65][66]. The lowest LOD reported corresponds to a sandwich assay using this last detection system [65].…”
Section: Individual Determinationsmentioning
confidence: 99%