2000
DOI: 10.1016/s0032-3861(00)00002-1
|View full text |Cite
|
Sign up to set email alerts
|

Residual stress and microstructures of aromatic polyimide with different imidization processes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

2003
2003
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(26 citation statements)
references
References 13 publications
0
26
0
Order By: Relevance
“…The details about the transformation from initial polyamic acid (PAA) liquid precursor with open-ring state to final solid polyimide film with close imide ring can be found elsewhere. 11) In comparison to the Nishino's work for two-step and stepwise curing profile, this study adopts the simple one-step curing profile where the average ramp up rate is 2.0 C/min and the average ramp down rate is 4.0 C/min. The finally curing thickness is 6 mm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The details about the transformation from initial polyamic acid (PAA) liquid precursor with open-ring state to final solid polyimide film with close imide ring can be found elsewhere. 11) In comparison to the Nishino's work for two-step and stepwise curing profile, this study adopts the simple one-step curing profile where the average ramp up rate is 2.0 C/min and the average ramp down rate is 4.0 C/min. The finally curing thickness is 6 mm.…”
Section: Methodsmentioning
confidence: 99%
“…The scan resolution is 4 cm À1 and scan number is 16. The general definition of curing rate (thermal imidization) means the percentage of polyimide precursor conversion to polyimide, the calculation method for area intensity is listed as follows: 11,[15][16][17] Relative curing rate…”
Section: Methodsmentioning
confidence: 99%
“…The curing degree can be determined by the conventional conversion equation. If one peak at 1380 cm À1 band is assigned to C-N stretching vibration of imide ring, and the other peak at 1500 cm À1 band is assigned to C-C stretching vibration of benzene, 28) then the curing degree can be defined as:…”
Section: Ftir Spectra Of Pi Filmmentioning
confidence: 99%
“…In addition, it is difficult to fabricate patterns with high resolutions and high-precisions in polyimide films because polyimide is difficult to etch or to dissolve away by a conventional photolithography and etching processes [15][16][17]. Furthermore, fine patterns with rectangular cross-sections and well defined line-edges are difficult to achieve due to a large shrinkage (30 -60%) resulting from the thermal imidization reaction of the polyimide precursor [18][19][20][21].…”
Section: Introductionmentioning
confidence: 99%