1989
DOI: 10.1016/0168-9002(89)91188-1
|View full text |Cite
|
Sign up to set email alerts
|

Residual gas beam profile monitor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1990
1990
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…The following conclusion can be drawn from the linear equation (1): the beam distribution can be measured simultaneously in two mutually perpendicular directions. To accomplish this, it is necessary to determine the sign of the coefficient of the variable in (1) and, in the simplest case (for which ), to transform (1) to the form: (2) If this condition is met, the slope coefficient of the straight line is equal to unity.…”
Section: Ibpm: Principle Of Operation and Designmentioning
confidence: 99%
“…The following conclusion can be drawn from the linear equation (1): the beam distribution can be measured simultaneously in two mutually perpendicular directions. To accomplish this, it is necessary to determine the sign of the coefficient of the variable in (1) and, in the simplest case (for which ), to transform (1) to the form: (2) If this condition is met, the slope coefficient of the straight line is equal to unity.…”
Section: Ibpm: Principle Of Operation and Designmentioning
confidence: 99%
“…The first use of IPMs dates back to the 1960s [4]. In the 90s, the raise of the MicroChannel Plates have permitted to measure profiles [5], [6] in more critical working conditions. The IPM method is now mature and used in several installations [7]- [10].…”
Section: Ionization Profile Monitors a State Of Artmentioning
confidence: 99%
“…Traditionally the first stage of the detector for an IPM has been a micro-channel plate (MCP) which acts as a charge amplifier [6]. After it is used, each channel in the plate require some time to recover and more importantly the lifetime of each channel is limited.…”
Section: Beam Gas Ionization Profile Monitormentioning
confidence: 99%
“…This early step to a digital signal is advantageous in many ways and in strong contrast to other ionization profile monitors where the signal is kept analog longer in the signal path. In [6] anode strips are used for the readout which are sampled with an ADC. Before a beam profile measurement is taken, the system background is sampled and stored and later subtracted from the measurements.…”
Section: Data Readout and Processingmentioning
confidence: 99%