2020
DOI: 10.1016/j.watres.2019.115439
|View full text |Cite
|
Sign up to set email alerts
|

Residential water heater cleaning and occurrence of Legionella in Flint, MI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
19
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2

Relationship

4
4

Authors

Journals

citations
Cited by 17 publications
(22 citation statements)
references
References 37 publications
2
19
0
Order By: Relevance
“…Routine maintenance and initial startup procedures (e.g., softener resin replacement or cleaning and disinfection, filter replacement) can serve as a starting point. Adapting existing recommendations should focus on ways to fully overturn the storage volume and remove accumulated sediment/biofilm (Masters et al, 2018; Rhoads et al, 2020).…”
Section: Resultsmentioning
confidence: 99%
“…Routine maintenance and initial startup procedures (e.g., softener resin replacement or cleaning and disinfection, filter replacement) can serve as a starting point. Adapting existing recommendations should focus on ways to fully overturn the storage volume and remove accumulated sediment/biofilm (Masters et al, 2018; Rhoads et al, 2020).…”
Section: Resultsmentioning
confidence: 99%
“…30,93 However, observed water temperature at distal fixtures may not always be helpful in predicting L. pneumophila concentrations because distal sampling locations acclimate to ambient temperature. 64,86,94 Therefore, approaches that incorporate wholebuilding temperature profiling may be more effective for assessing the influence of hot water temperature on L. pneumophila. 91 Intermittent heating, and other energy-saving methods have previously been linked to lower water qualities due to decreased hot water temperatures in building plumbing.…”
Section: Sample Temperature and Ph Were Not Associated With L Pneumop...mentioning
confidence: 99%
“…Recirculating systems can also accumulate 3-20 times more sediments [222] arising from corrosion of metallic pipe material and the anode rods [157,[232][233][234]258]. These sediments, which also collect at the bottom of hot water tanks, may serve as an important growth niche within warm regions of hot water tanks where influent cold water depresses temperatures, and there are also relatively low levels of disinfectant and high levels of nutrients for Legionella, heterotrophs, and host organisms [17,259].…”
Section: Hot Water Recirculation Linesmentioning
confidence: 99%