Order By: Relevance
“…The expression of CD36 antigen has been shown to vary according to geographic region (Table 4, Table 5). In the present study, the frequency of CD36 deficiency was estimated to be 2.64% in 13,778 cases of individuals in China, significantly lower than reported in other Asian countries [[10], [13]]. In addition, the frequency of type I CD36 deficiency was significantly lower in northern regions than in southern regions, with no difference in the frequency of type II CD36 deficiency observed between regions.…”
Section: Discussioncontrasting
confidence: 68%
“…The expression of CD36 antigen has been shown to vary according to geographic region (Table 4, Table 5). In the present study, the frequency of CD36 deficiency was estimated to be 2.64% in 13,778 cases of individuals in China, significantly lower than reported in other Asian countries [[10], [13]]. In addition, the frequency of type I CD36 deficiency was significantly lower in northern regions than in southern regions, with no difference in the frequency of type II CD36 deficiency observed between regions.…”
Section: Discussioncontrasting
confidence: 68%
“…Platelet transfusion is generally used either prophylactically to reduce the risk of bleeding or therapeutically to control active bleeding in many clinical settings . Liquid‐preserved platelets kept under standard blood banking conditions, at 20 to 24 °C with constant agitation, can be stored for only 5 to 7 days, which severely limits their availability at far‐forward combat facilities and remote civilian locations …”
mentioning
confidence: 99%
“…Platelets were obtained by separating whole blood from Spectra Optia Blood Cell Separator (Carlsbad, CA, USA), and the number of platelets in each bag was ≥2.5×10 11 /L, and were transfused within 24 hours on the day of collection or stored at 4°C. Unrelated platelets were provided by Jinhua Blood Center and met the requirements of Chinese quality standards 11 . Each bag platelets is 9-12 units, and the number of platelets is ≥2.5×10 11 /L.…”
Section: Platelet Products and Transfusion Policymentioning