2013
DOI: 10.1007/s11803-013-0172-2
|View full text |Cite
|
Sign up to set email alerts
|

Research on wind-induced responses of a large-scale membrane structure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 22 publications
(5 citation statements)
references
References 3 publications
0
5
0
Order By: Relevance
“…The wind tunnel tests can well restore and reflect the load size and vibration of the membrane structure in the actual use process [49,50]. In order to reduce the error caused by the similarity ratio conversion process of physical parameters and keep the same parameters with the model of numerical simulation below, the similarity theory is not considered in the wind tunnel test.…”
Section: Wind Tunnel Testsmentioning
confidence: 99%
“…The wind tunnel tests can well restore and reflect the load size and vibration of the membrane structure in the actual use process [49,50]. In order to reduce the error caused by the similarity ratio conversion process of physical parameters and keep the same parameters with the model of numerical simulation below, the similarity theory is not considered in the wind tunnel test.…”
Section: Wind Tunnel Testsmentioning
confidence: 99%
“…Standard k-ε, realizable k-ε, and SST k-ω were used to investigate the average wind pressure distributions for hyperbolic paraboloid form. Few studies examined the aerodynamic effect of spatial structures such as conical form and canopies [13,14], hypar roof [15], large-scale membrane structure [16], and conical canopies as reversed type [17,18]. The main concern that needs to specify is how the aerodynamic parameters would be changed by various wind directions, in particular for TMS that are sensitive to wind load as well as orientations.…”
Section: Introductionmentioning
confidence: 99%
“…On the other hand, it is hard to determine the architectural performance of membrane structures based on the research findings on traditional structures, as the gap between membrane materials and traditional building materials is pronounced [12]. A lightweight and flexible nature signifies that the structure exhibits intense geometric nonlinearity [13]. Accurate structural analysis is essential for membrane buildings and facilitates the formation of design principles [14].…”
Section: Introductionmentioning
confidence: 99%