2019
DOI: 10.1109/access.2019.2920659
|View full text |Cite
|
Sign up to set email alerts
|

Research on Transmission Line Voltage Measurement Method Based on Improved Gaussian Integral

Abstract: Currently, there are two non-contact measurement methods of the transmission line voltage based on field sensor: one is calculation with the inverse problem of electric field for the solution, and the other is to solve by the numerical integration algorithm. In general, the first one is confronted with data equation solving problems and difficulties in accurate calibration as well as low precision, while the second one is troubled by the complexity of algorithm equation and unsatisfactory integration node. In … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…However, this measurement was carried out under relatively ideal conditions. Furthermore, the research group derived different integral algorithms from the Gauss numerical integral to calculate the transmission line voltage, including G-L (Gauss–Legendre) numerical integration, I-G-L (improved Gauss–Legendre) numerical integration, G-C (Gauss–Chebyshev) numerical integration, and G-K (Gauss–Kronrod) numerical integration, where the highest measurement accuracy was obtained (up to 0.3%) with G-K [ 18 , 19 , 20 , 21 ]. In addition, the researchers presented a scheme for reconstructing the parameters of the integral nodes to improve the accuracy of the solution results [ 22 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, this measurement was carried out under relatively ideal conditions. Furthermore, the research group derived different integral algorithms from the Gauss numerical integral to calculate the transmission line voltage, including G-L (Gauss–Legendre) numerical integration, I-G-L (improved Gauss–Legendre) numerical integration, G-C (Gauss–Chebyshev) numerical integration, and G-K (Gauss–Kronrod) numerical integration, where the highest measurement accuracy was obtained (up to 0.3%) with G-K [ 18 , 19 , 20 , 21 ]. In addition, the researchers presented a scheme for reconstructing the parameters of the integral nodes to improve the accuracy of the solution results [ 22 ].…”
Section: Introductionmentioning
confidence: 99%
“…Although most publications related to field-source numerical integration problems have proposed many numerical integration methods and optimal schemes for reducing the measurement error, there is a lack of an effective comparison and evaluation concerning the accuracy and stability of various electric field integration algorithms. The literature mentioned above [ 17 , 18 , 19 , 20 , 21 ] selected different integration algorithms to compare the accuracy of the final measurement results. The current research does not discuss the possible error sources in actual applications and the influence of error propagation on the final voltage measurement results, resulting in the inability to optimize the numerical integration method for calculating the transmission line voltage from the sources of error, and the difficulties in practical application.…”
Section: Introductionmentioning
confidence: 99%
“…However, the results were obtained under the ideal conditions, and some issues were actually minimized, such as the unstable measurement performance caused by the relatively fixed nodes information and the nonlinear E-field distribution. Li Xiang [29] has improved the Gaussian integration algorithm, in order to obtain better insulation performance of the sensors while ensuring the good measurement accuracy. A flaw is that this research ignored the other interference sources that may be caused when the sensor position moves downward.…”
Section: Introductionmentioning
confidence: 99%