Research on the Real-Time Phase Jump Process Method for Plasma Electron Density Measurement in HL-2A Tokamak

Abstract: In the real-time plasma electron density measurement using far infrared (FIR) laser interferometry, the plasma electron density can be calculated by measuring the real time phase difference between the reference signal and the probe signal. A novel Real-time Phase Jump Process (RPJP) method is applied to the HL-2A tokamak. With this method, the phase difference precision is up to 1 3600 fringe (1 fringe is equal to a phase shift of 2π), and the dynamic measurement range is extensible 65536 fringes. The time re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…Next, the lineintegrated density can be computed from the ratio of these amplitudes. Finally, the Real-time Phase Jump Process [18] corrects the fringe jump errors and transfers the data to the PXIe controller through PXIe bus.…”
Section: Hardware Description Of Pa Methodsmentioning
confidence: 99%
“…Next, the lineintegrated density can be computed from the ratio of these amplitudes. Finally, the Real-time Phase Jump Process [18] corrects the fringe jump errors and transfers the data to the PXIe controller through PXIe bus.…”
Section: Hardware Description Of Pa Methodsmentioning
confidence: 99%
“…A well-known problem with this method is the fringe jump that arises from the phase comparison technique, due to the arcus-tangent function (when the phase difference reaches π or −π). To obtain a valid and reliable electron density, the phase information with a fringe jump needs to be unwrapped [10][11][12][13][14][15][16]. Accurate and real-time fringe counting method is essential for the plasma control system (PCS), especially for electron density feedback control.…”
Section: Fringe Jump In the Hcn Interferometer On Eastmentioning
confidence: 99%
“…module is adopted [26], and the maximum range can reach up to 65536 fringes. Finally, the PXIE Interface and Time-stamp module upload the raw data, time-stamp and the phase difference and send digital data to DAC for analog feedback.…”
Section: Jinst 17 P09037mentioning
confidence: 99%