Abstract:To explore the influence of calibration position on digital image correlation measurement of dual cameras in engineering application, an experimental method of displacement stepping for digital image correlation measurement of dual cameras under different calibration locations is designed. Through precise displacement stepping of samples, the results of digital image correlation measurement and dial gauge measurement are compared. The influence of different calibration locations on the measurement results of d… Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.