2019 14th IEEE Conference on Industrial Electronics and Applications (ICIEA) 2019
DOI: 10.1109/iciea.2019.8834104
|View full text |Cite
|
Sign up to set email alerts
|

Research on Pre-Synchronization Control Strategy for Microgrid VSG Inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…The detected three-phase voltage and current at the parallel network, ucabc and icabc are Clark-transformed to obtain the components ucαβ and icαβ on the αβ0 coordinate axis. The instantaneous value of the inverter output three-phase voltage, E0, can be obtained from ( 9) and (10)…”
Section: Analysis Of Vsg Nadrc Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…The detected three-phase voltage and current at the parallel network, ucabc and icabc are Clark-transformed to obtain the components ucαβ and icαβ on the αβ0 coordinate axis. The instantaneous value of the inverter output three-phase voltage, E0, can be obtained from ( 9) and (10)…”
Section: Analysis Of Vsg Nadrc Modelmentioning
confidence: 99%
“…By separating the positive and negative sequence components of voltage, the unbalance of output voltage under unbalanced load condition is reduced. In addition, in the integrated compensation VSG control strategy, the frequency deviation caused by load disturbance is eliminated by the parallel integration compensator on the damping coefficient D [10], which improves the frequency modulation performance of the VSG system and inhibits the power oscillation of the VSG system. However, the experimental results of VSG voltage regulation capability and power quality are lacking.…”
Section: Introductionmentioning
confidence: 99%
“…In order to avoid system damage due to excessive power impact of VSG at the moment of grid connection, it is necessary to realize the output voltage of VSG with the same voltage amplitude and phase as the grid during grid connection switching. This process is called "pre-synchronization control of VSG" [8], [9]. For the VSG grid connection switching control or the pre-synchronization control, in [10], an integral element is added in the active and reactive power droop control to realize the VSG to track the grid frequency and voltage with zero static error firstly.…”
Section: Introductionmentioning
confidence: 99%