2018
DOI: 10.1049/iet-gtd.2017.2032
|View full text |Cite
|
Sign up to set email alerts
|

Research on heat and electricity coordinated dispatch model for better integration of wind power based on electric boiler with thermal storage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
17
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 33 publications
(17 citation statements)
references
References 29 publications
0
17
0
Order By: Relevance
“…Simulation results demonstrate that the dispatch model is efficient to reduce the emissions of CO2, SO2, and NOx, and increase the wind power accommodation. The following conclusions can be drawn: (1) The emissions of CO2, SO2, and NOx could be reduced, and the wind power accommodation could be promoted, when considering the environmental cost in an economic dispatch model; (2) environmental costs can be counted as the cost of power generation, since the environmental cost is closely related to the amount of coal burned; and (3) environmental cost accounts for a certain…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Simulation results demonstrate that the dispatch model is efficient to reduce the emissions of CO2, SO2, and NOx, and increase the wind power accommodation. The following conclusions can be drawn: (1) The emissions of CO2, SO2, and NOx could be reduced, and the wind power accommodation could be promoted, when considering the environmental cost in an economic dispatch model; (2) environmental costs can be counted as the cost of power generation, since the environmental cost is closely related to the amount of coal burned; and (3) environmental cost accounts for a certain…”
Section: Discussionmentioning
confidence: 99%
“…In recent years, clean energy is promoted all over the world to reduce environmental pollution. Although China is rich in wind energy resources, the main operation pattern "determining power by heat" for combined heat and power (CHP) and the "anti-peak regulation" character of wind power in heating season causes severe wind curtailment [1,2]. In the heating season, the thermal load demand of consumers must be met, but the thermal power constrains the electrical power of CHP.…”
Section: Introductionmentioning
confidence: 99%
“…Step 2: A criterion, denoted as deta WF , is derived by Equation (26) to judge whether the generated wind power is surplus or not.…”
Section: Self-repair Methodsmentioning
confidence: 99%
“…As popular as the HS is employed in the CHPS, 23 the EB and the HP are usually utilized to consume surplus wind power by converting it into thermal power. 24,25 The authors in reference 26 explore the effectiveness of the EB incorporated with heat storages on the improvement of wind power integration and propose a start-stop strategy for the control of the EB and heat storages. The performance of the EB and the HP in the CHPS of West Denmark is compared in reference.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation