2020
DOI: 10.3390/s20092718
|View full text |Cite
|
Sign up to set email alerts
|

Research on Focal Length Measurement Scheme of Self-Collimating Optical Instrument Based on Double Grating

Abstract: In this paper, we propose a scheme for measuring the focal length of a collimating optical instrument. First, a mathematical model for measuring the focal length of a collimator with double gratings is derived based on the moiré fringe formula and the principles of geometric optics. Mathematical simulation shows that a slight difference in the focal length of two collimators has an important influence on the imaging law of moiré fringes. Our solution has a good resolution ability for focal length differences w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…This article presented a procedure for calibrating ophthalmic lenses. Additionally, it proposed a mathematical model for estimating uncertainty based on a non-stochastic methodology such as the Guide for the Expression of Measurement Uncertainty (GUM) [11] and the application of dimensional metrology concepts. This study also identified sources of uncertainty that had not been previously observed or analyzed in most research papers in the literature.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…This article presented a procedure for calibrating ophthalmic lenses. Additionally, it proposed a mathematical model for estimating uncertainty based on a non-stochastic methodology such as the Guide for the Expression of Measurement Uncertainty (GUM) [11] and the application of dimensional metrology concepts. This study also identified sources of uncertainty that had not been previously observed or analyzed in most research papers in the literature.…”
Section: Discussionmentioning
confidence: 99%
“…Applying the expression above to the function of ophthalmic lens calibration and considering the sources of uncertainty established in ( 1) and ( 4), the output variable is given by ( 10): 𝑃 = 𝑓(𝑑 𝑗 , 𝐶 𝑃 , 𝐶 𝐴 , 𝐶 𝑇 , 𝐶 𝐷𝐸 ) (10) Applying ( 8) in ( 1) and (3), we obtain (11):…”
Section: Mathematical Model For Determining Uncertainty and Error In The Calibration Process Of Ophthalmic Lensesmentioning
confidence: 99%
See 1 more Smart Citation
“…The electro-optical unmanned system driven by the cable frequently will suffer from mechanical wear and fracture of the cable. To solve this problem, the rope pulley interaction of the cable traction device is analyzed, and the scientific method for the rational design of the cable traction system is studied [12][13] . As shown in Figure 3, when the human does not exert external traction torque, under the effect of preload 𝑇 𝑝𝑟𝑒𝑙𝑜𝑎𝑑 , the tension 𝑇 1 at the rope inlet end, and the tension 𝑇 2 at the rope outlet end is (8).…”
Section: Mechanical Analysismentioning
confidence: 99%
“…6(a) is a captured moiré image, an image processing series, i.e., filtering, contrast enhancement, threshold segmentation, corrosion, and thinning, converts these stripes into single-pixel lines as shown in Fig. 6(b) [24]. If the average horizontal spacing between these lines is denoted as x and vertical spacing as y, the width W of moiré fringe can be calculated as follows:…”
Section: Receiving Part Collimatormentioning
confidence: 99%