2020
DOI: 10.1007/s12273-020-0685-3
|View full text |Cite
|
Sign up to set email alerts
|

Research on air infiltration predictive models for residential building at different pressure

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…Chan et al, 2,22 Montoya et al, 21 Pan, 5 Fernàndez-Agüera et al 28 and Bramiana et al 31 presented empirical regression predictive models using several regression analyses on airtightness. In addition, Li et al 40 presented several regression methods including ordinary least squares (OLS), stepwise regression, partial least squares (PLS) and nonlinear fitting with independent variable screening methods to establish an airflow coefficient model. The simulation results show that the improvement with the nonlinear fitting was weaker.…”
Section: Current Research Of Air Leakage Prediction Models and Resear...mentioning
confidence: 99%
“…Chan et al, 2,22 Montoya et al, 21 Pan, 5 Fernàndez-Agüera et al 28 and Bramiana et al 31 presented empirical regression predictive models using several regression analyses on airtightness. In addition, Li et al 40 presented several regression methods including ordinary least squares (OLS), stepwise regression, partial least squares (PLS) and nonlinear fitting with independent variable screening methods to establish an airflow coefficient model. The simulation results show that the improvement with the nonlinear fitting was weaker.…”
Section: Current Research Of Air Leakage Prediction Models and Resear...mentioning
confidence: 99%
“…The airtightness value in natural conditions is quite a bit lower than that under a 50 Pa pressure difference between indoors and outdoors. Specifically, the pressure difference between indoors and outdoors under the natural airflow condition is lower than 10 Pa [26]. Generally, the tracer gas method has been used to measure infiltration under natural air flow conditions, and it can provide a more reliable result than that offered by the fan pressurization method [27][28][29].…”
Section: Introduction 1background and Objectivementioning
confidence: 99%
“…In terms of quality, when establishing its management plan, there may be project deliverables and processes, related to sustainability, that need to be checked for quality. For example, in the construction of houses according to the Passivhaus (passive house in translation) standard [86,87], it will be necessary to perform tests to detect air penetration through doors and windows and thus assess the permeability of the building envelope (BlowerDoor Test; [88,89]).…”
mentioning