2019
DOI: 10.32014/2019.2518-170x.115
|View full text |Cite
|
Sign up to set email alerts
|

Research of Systematic Errors According to the Results of Processing Satellite Observations by Software Complexes

Abstract: NAS RK is pleased to announce that News of NAS RK. Series of geology and technical sciences scientific journal has been accepted for indexing in the Emerging Sources Citation Index, a new edition of Web of Science. Content in this index is under consideration by Clarivate Analytics to be accepted in the Science Citation Index Expanded, the Social Sciences Citation Index, and the Arts & Humanities Citation Index. The quality and depth of content Web of Science offers to researchers, authors, publishers, and ins… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…The circuit for transmission and processing of the measuring signal is shown in Figure 1. The measured value by its size is a random value of the error of its measurement is also random (when eliminating the systematic component of the error; the study of systematic errors is considered, for example, in Tereshchuk et al, 2019). The random state of the object of measurement and its errors leads to some uncertainty, but before the measurements it is known that the value measured is within certain limits, and its value must be obtained with some degree of accuracy, the preliminary information about the size of the object reduces uncertainty and the expected error will show the limits of this uncertainty, i.e.…”
Section: Methodsmentioning
confidence: 99%
“…The circuit for transmission and processing of the measuring signal is shown in Figure 1. The measured value by its size is a random value of the error of its measurement is also random (when eliminating the systematic component of the error; the study of systematic errors is considered, for example, in Tereshchuk et al, 2019). The random state of the object of measurement and its errors leads to some uncertainty, but before the measurements it is known that the value measured is within certain limits, and its value must be obtained with some degree of accuracy, the preliminary information about the size of the object reduces uncertainty and the expected error will show the limits of this uncertainty, i.e.…”
Section: Methodsmentioning
confidence: 99%
“…Institute of space technique and technology, Almaty, Kazakhstan; 3 KTH Royal Institute of Technology, Stockholm, Sweden. E-mail: a.baltiyeva@gmail.com, raskaliyev@mail.ru, shamls@mail.ru, huaan.fan@abe.kth.se, gylxana@mail.ru…”
Section: N E W S Of the National Academy Of Sciences Of The Republic Of Kazakhstan Series Of Geology And Technical Sciencesmentioning
confidence: 99%
“…The reason for the discrepancy was the definition and assignment of coordinates of the base "basa kachar" and BSDC in different coordinate systems. The coordinates "basa kachar" were determined in the LCS of the Kacharsky open-pit mine, while the coordinates of the BSDC, according to the previously made draft and technical design, were determined in the international coordinate system ITRF-2014 [3,4].…”
Section: Acceptance Tests Of the Software And Technical Complex Of The High-precision Satellite Positioning System In The Kacharsky Minementioning
confidence: 99%
See 1 more Smart Citation
“…A number of works are also devoted to the processing of the obtained results of GNSS observations. For example, the paper (Tereshchuk et al, 2019) considers the processing of the results of field satellite GNSS measurements at the points of the State Geodetic Network of the Northern Region of Ukraine using OCTAVA and Graf-Nav/GrafNat software packages. Based on the results of the study, a method has been developed for estimating the accuracy of processing the results of GNSS observations by software packages based on the method of double nonequilibrium measurements.…”
Section: Introductionmentioning
confidence: 99%