2019
DOI: 10.1007/s00202-019-00876-9
|View full text |Cite
|
Sign up to set email alerts
|

Research of small oscillations of electrical power systems using the technology of embedding systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 23 publications
(24 citation statements)
references
References 6 publications
0
24
0
Order By: Relevance
“…Thus, expressions (12), (13), and (14) determine the equivalent parameters ∑g , ∑С and L0 NI EMT is distinguished by a sufficiently high accuracy in comparison with the known calculation formulas. The use of equivalent parameters of the generalized NI EMT model allows obtaining more accurate analytical expressions when calculating the equivalent circuit of ferroresonance with EMT and network capacities.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, expressions (12), (13), and (14) determine the equivalent parameters ∑g , ∑С and L0 NI EMT is distinguished by a sufficiently high accuracy in comparison with the known calculation formulas. The use of equivalent parameters of the generalized NI EMT model allows obtaining more accurate analytical expressions when calculating the equivalent circuit of ferroresonance with EMT and network capacities.…”
Section: Resultsmentioning
confidence: 99%
“…The Let's define an expression for instantaneous values of current and active power in NI EMT [8][9][10][11][12][13].…”
Section: Ferroresonance Research Using Generalized Models Of Passive mentioning
confidence: 99%
“…The frequency response of ATG with HMR is a complex curve, having a bulbous shape, due to the intensive displacement of the rotor current. As a result of the increased value of the inductive resistance of the rotor, the ATG with HMR has a slightly lower power factor and maximum torque compared to the rest of the ATG [24][25][26].…”
Section: Main Partmentioning
confidence: 99%
“…Therefore, a thorough study (energy audit) of energy consumption, analysis of operating modes of all types of electrical equipment and timely adjustment of operating modes, as well as their correct loading and operation, will significantly reduce electricity costs in general, and savings from electricity consumption can rise up to 30-40% compared to the original numbers [22][23][24][25][26][27][28].…”
Section: Figmentioning
confidence: 99%