2009 Asia-Pacific Power and Energy Engineering Conference 2009
DOI: 10.1109/appeec.2009.4918665
|View full text |Cite
|
Sign up to set email alerts
|

Research of Effect of Wind-Blown Rain on Power Frequency Flashover Characteristic of Conductor-Tower Air Gap

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
8
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 4 publications
0
8
0
Order By: Relevance
“…The rain effects on switching impulse spark-over voltage of different air gaps were studied [6][7][8]. In [6,7], full-scale experimental setups were carried out, and the breakdown performances of phase-to-ground and phase-to-phase insulation with different gap lengths in dry and wet conditions have been compared.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The rain effects on switching impulse spark-over voltage of different air gaps were studied [6][7][8]. In [6,7], full-scale experimental setups were carried out, and the breakdown performances of phase-to-ground and phase-to-phase insulation with different gap lengths in dry and wet conditions have been compared.…”
Section: Introductionmentioning
confidence: 99%
“…The results indicated that the water drops in the shielding ring should be the main reason for the decrease in breakdown voltage under rain conditions [7]. The effects of rain on the breakdown characteristics of conductor-to-tower air gaps under power frequency voltages were studied in [8,9], and the breakdown characteristics of rod to plane short air gaps under different voltages (switching [10], DC [11], AC [12]) have been investigated. It has been found that rain drops can reduce the insulation strength of the power systems under different kinds of applied voltages.…”
Section: Introductionmentioning
confidence: 99%
“…In 2002, Yamagata carried out the full-scale experiment on insulation with different gap lengths in dry and wet conditions using shielding rings [7]. Hu [8] studied the influence of rain and wind on power frequency breakdown characteristic of conductor-to-tower clearance in 2008. These literatures offered convincing data about the breakdown characteristics of air clearance based on experiments.…”
Section: Introductionmentioning
confidence: 99%
“…Results about breakdown performance and analysis of air gap under rain conditions can be found in [2][3][4][5][6][7][8]. Rizk [2][3] investigated the influence of rain on switching impulse spark-over voltage of sphere-plane, toroid-plane and rod-plane air gap.…”
Section: Introductionmentioning
confidence: 99%
“…He pointed that that the effect of water drops on the shielding ring should be considered as the main reason for the decrease in breakdown voltage in wet tests. In [5], the influence of rain and wind on power frequency discharge characteristic of conductor-to-tower air gap was investigated to describe the effect of rain intensity and rain conductivity on the discharge voltage of conductor-to-tower air gap. Xingliang Jiang [6][7] reported the ac breakdown characteristics of rod-plane air gap in rain conditions.…”
Section: Introductionmentioning
confidence: 99%