2004
DOI: 10.1063/1.1785270
|View full text |Cite
|
Sign up to set email alerts
|

Research and development of x-ray imaging crystal spectrometers for KSTAR

Abstract: The engineering design for two high-resolution x-ray imaging crystal spectrometers for KSTAR tokamak has been completed. A spherically bent quartz crystal and a large area two-dimensional (2D) position-sensitive multiwire proportional counter have been selected for the imaging spectrometers. A prototype 10 cm by 30 cm 2D detector was fabricated and pilot measurement on Alcator C-Mod tokamak was carried out. The final engineering design of the spectrometers and experimental results from the 2D detector are pres… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
13
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(13 citation statements)
references
References 3 publications
0
13
0
Order By: Relevance
“…The x-ray crystal spectrometer (XCS) was proposed to measure the x-ray lines from helium like argon Ar XVII in the KSTAR tokamak plasma [2]. Figure 9 shows a horizontal XCS, providing ion and electron temperature profiles, which will be installed at the horizontal midplane of the KSTAR machine.…”
Section: Technical Issues In the Design For The Calibration Of The Ksmentioning
confidence: 99%
See 3 more Smart Citations
“…The x-ray crystal spectrometer (XCS) was proposed to measure the x-ray lines from helium like argon Ar XVII in the KSTAR tokamak plasma [2]. Figure 9 shows a horizontal XCS, providing ion and electron temperature profiles, which will be installed at the horizontal midplane of the KSTAR machine.…”
Section: Technical Issues In the Design For The Calibration Of The Ksmentioning
confidence: 99%
“…Some technical issues in the application of the x-ray tube to the calibration are following : It is required that the 2D detector, the crystal and the x-ray source should be positioned on the Rowland circle in order to expose the best focused x-rays on the detector. To get the line focused x-ray source, a slit with a gap of about 50 µm is positioned in front of the x-ray tube, which experienced in the position calibration using a 55 Fe source in a laboratory [2]. It is essential to investigate the spatial resolution in the detector required for the image measurement.…”
Section: Technical Issues In the Design For The Calibration Of The Ksmentioning
confidence: 99%
See 2 more Smart Citations
“…[282][283][284][285] The instrument consists of a spherically bent crystal and a two-dimensional detector, which are arranged in a Johann configuration. The imaging properties of this configuration have been discussed by Bitter et al 252 and Bertschinger et al…”
Section: New Instrumental Developmentsmentioning
confidence: 99%