2004
DOI: 10.1002/sia.1827
|View full text |Cite
|
Sign up to set email alerts
|

Reproducible XPS on biopolymers: cellulose studies

Abstract: The development of 'user-friendly' surface analytical instrumentation has expanded the application of x-ray photoelectron spectroscopy (XPS) towards softer and more complex composite materials. However, the knowledge of fundamental phenomena in practical, interdisciplinary applications is dearly needed. In the case of polymers and polymer-based or -reinforced composites, the analytical problems are not only related to detection limits and resolution; indeed, the effects of contamination and experimental artefa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

16
221
0
1

Year Published

2006
2006
2023
2023

Publication Types

Select...
9
1

Relationship

4
6

Authors

Journals

citations
Cited by 251 publications
(238 citation statements)
references
References 5 publications
16
221
0
1
Order By: Relevance
“…The pump was then stopped and started again (0.1 mL/min) after 3 h (4 h in the case of EG I) of treatment to rinse the system with buffer solution. All measurements were recorded at 5 MHz fundamental resonance frequency and its overtones corresponding to 15,25,35,55, and 75 MHz. The third overtone (15 MHz) was used for data processing.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…The pump was then stopped and started again (0.1 mL/min) after 3 h (4 h in the case of EG I) of treatment to rinse the system with buffer solution. All measurements were recorded at 5 MHz fundamental resonance frequency and its overtones corresponding to 15,25,35,55, and 75 MHz. The third overtone (15 MHz) was used for data processing.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…The power applied to the X-ray anode was reduced to 90 W to avoid sample degradation. 7,8 The instrument work function was calibrated to give a BE of 83.96 eV for the Au 4f 7/2 line for metallic gold. The samples were then kept under vacuum overnight prior to analyses.…”
Section: Xps Analysismentioning
confidence: 99%
“…A fresh piece of 100% cellulose was measured with each sample batch, as an in-situ reference. [58] Elemental surface compositions were determined from low resolution survey spectra (1 eV step, 80 eV CAE), while the high resolution regional data of C 1s, O 1s, Cl 2p and N 1s were used in detailed chemical analysis (0.1 eV step, 20 eV CAE). The aliphatic component in high resolution C 1s peak at 285.0 eV was utilized as the binding energy reference for all spectra.…”
Section: Methodsmentioning
confidence: 99%