2017
DOI: 10.1016/j.radi.2017.03.011
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility of ultrasound-derived muscle thickness and echo-intensity for the entire quadriceps femoris muscle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
21
0
3

Year Published

2018
2018
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(30 citation statements)
references
References 41 publications
6
21
0
3
Order By: Relevance
“…medial gastrocnemius, quadriceps, hamstrings, and biceps brachii), with different populations (men or women, young or elderly, and healthy or unhealthy) and in different positions (sitting or standing). 4,[7][8][9][10][11][12][13][14][15][16] However, the results are not consistent amongst them, with reported reliabilities changing considerably from one study to another, with ICC values ranging between 0.31 and 0.96. 4,[7][8][9][10][11][12][13][14][15][16] Studies that evaluate inter-rater and inter-analyst reliability are scarce in the literature.…”
Section: Introductionmentioning
confidence: 73%
See 1 more Smart Citation
“…medial gastrocnemius, quadriceps, hamstrings, and biceps brachii), with different populations (men or women, young or elderly, and healthy or unhealthy) and in different positions (sitting or standing). 4,[7][8][9][10][11][12][13][14][15][16] However, the results are not consistent amongst them, with reported reliabilities changing considerably from one study to another, with ICC values ranging between 0.31 and 0.96. 4,[7][8][9][10][11][12][13][14][15][16] Studies that evaluate inter-rater and inter-analyst reliability are scarce in the literature.…”
Section: Introductionmentioning
confidence: 73%
“…Specifically, in the RF, ICCs ranged between 0.31 and 0.91. 7,9,[12][13][14]16 Ruas et al 12 reported SEMs of 8.81% (MDs ¼ 24.44%) of the mean EI value, Tomko et al 16 found SEM values ranging from 6.46% to 8.12% of the mean EI, while Santos and Armada-da-Silva 13 reported SEMs ranging from 2.06 to 3.61 (a.u. ).…”
Section: Discussionmentioning
confidence: 99%
“…Sample size was determined using mean and standard deviation data from a study that evaluated the same variable in a similar population. 22 Sixteen healthy young subjects (eight men and eight women; age, 27.56 ± 1.71 years; body mass index [BMI], 23.64 ± 2.79 kg/m 2 ) volunteered to participate in the study. All US images were obtained on the same day while subjects were laying down on a stretcher in a supine position with their knees fully extended.…”
Section: Methodsmentioning
confidence: 99%
“…34 A concern for the use of EI parameter is the poor inter-rater correlation (ICC: 0.21-0.65) reported by some authors 44,50 although good intra-rater correlation has been achieved (ICC: 0.84-0.96). 55,61,62 This could be due to the effects of region of interest (ROI) size and its relation to EI. A study showed that EI reliability and repeatability were a function of ROI size and shape 63 (►Fig.…”
Section: Echo Intensitymentioning
confidence: 99%