Reproducibility of methods for assessing baroreflex sensitivity and temporal QT variability in end-stage renal disease and healthy subjects

Abstract: Spontaneous baroreflex sensitivity (BRS), the reflex heart rate modulation in response to blood pressure changes (predominantly an index of cardiac vagal activity) and temporal QT variability (an index of myocardial repolarization) have been demonstrated to convey important prognostic information. The information about reproducibility of BRS and temporal QT variability is limited and there is lack of information regarding patients with cardiovascular diseases. We investigated reproducibility of spontaneous BRS… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
19
0

Year Published

2005
2005
2014
2014

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(20 citation statements)
references
References 23 publications
1
19
0
Order By: Relevance
“…However, in patient groups with known impairment of the baroreflex such as heart failure and end stage renal failure, BRS derived by both the sequence and the spectral methods have been shown to be less reproducible than has been demonstrated in studies of healthy individuals [7,11]. Patients with cerebrovascular disease have BRS values similar to these subjects and thus the measurement of BRS may not be as reproducible as predicted by the studies in healthy individuals.…”
Section: Introductionmentioning
confidence: 81%
See 1 more Smart Citation
“…However, in patient groups with known impairment of the baroreflex such as heart failure and end stage renal failure, BRS derived by both the sequence and the spectral methods have been shown to be less reproducible than has been demonstrated in studies of healthy individuals [7,11]. Patients with cerebrovascular disease have BRS values similar to these subjects and thus the measurement of BRS may not be as reproducible as predicted by the studies in healthy individuals.…”
Section: Introductionmentioning
confidence: 81%
“…This difference in methodology may explain the poor reproducibility seen by Davies et al Indeed, when we assessed our reproduc- Spectral analysis is presented as total power (Spectral BRS) and its low frequency (LF) and high frequency (HF) components, sequence analysis is presented as all sequences and its up sequence and low sequence components ibility using just a single 5-minute recording at each visit, we found the method to be much less reproducible with CVs of 35.7% for spectral and 42.4% for sequence analysis. Gao et al [11] assessed the reproducibility of BRS by sequence analysis in subjects with end-stage renal disease at two visits at a mean of 7 days apart. They found reproducibility in this patient group to be almost as good as for their healthy control group (CV 33% cf 27%), and similar to those described in stroke patients in the current study.…”
Section: Discussionmentioning
confidence: 99%
“…Increased sympathetic or decreased parasympathetic nervous system activity predisposes patients with Coronary Heart Disease (CHD) to ventricular tachycardia, ventricular fibrillation, sudden cardiac death [9,10] and increased mortality [11]. Decreased vagal activity and increased sympathetic activity, both of which are risk factors predicting death was found in both healthy adults and adults with exit cardiovascular disease [22][23][24][25][26][27]. Heart Rate Turbulence (HRT) and Heart Rate Variability (HRV) are a comprehensive evaluation of cardiac autonomic reflexes [13].…”
Section: Discussionmentioning
confidence: 99%
“…First, most if not all require that the operator actively perform certain functions, for example that he or she manually choose the onset and offset of an initial QT interval template. This step of human intervention is both time and labor consuming, and affects reproducibility (12). Second, the majority of these existing programs also allow for QTV analyses in only one single channel at a time (i.e., usually in limb lead II or limb lead I), and not in multiple channels simultaneously.…”
Section: Introductionmentioning
confidence: 99%