2001
DOI: 10.1016/s0925-4927(01)00071-3
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility of in vivo brain measures of 5-HT2A receptors with PET and [18F]deuteroaltanserin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 22 publications
0
11
0
Order By: Relevance
“…In humans, cortical‐to‐cerebellar ratio was increased by 26% above that observed previously for [ 18 F]altanserin, suggesting it might be a superior PET radioligand . In a subsequent study by the same group, the test–retest reliability was also quite good …”
Section: Current Radioligands For Imaging the 5‐ht Systemmentioning
confidence: 51%
“…In humans, cortical‐to‐cerebellar ratio was increased by 26% above that observed previously for [ 18 F]altanserin, suggesting it might be a superior PET radioligand . In a subsequent study by the same group, the test–retest reliability was also quite good …”
Section: Current Radioligands For Imaging the 5‐ht Systemmentioning
confidence: 51%
“…The replacement of hydrogen with deuterium in [ 18 F]altanserin reduces the rate of undesirable radiometabolite formation. [ 18 F]deuteroaltanserin shows better characteristics and 26% higher brain uptake than [ 18 F]altanserin itself in nonhuman primates and human [102, 103]. Although higher binding in estrogen replacement and lower binding in cortical regions of AD are reported using [ 18 F]deuteroaltanserin, not many studies are available at present to thoroughly assess its potential [104].…”
Section: Introductionmentioning
confidence: 99%
“…The radiotracers [ 18 F]-altanserin, [ 11 C]-MDL100,907, and [ 18 F]-setoperone have been used to study cortical 5HT 2A R in neurochemical PET imaging studies [12,14,16-21]. Test-retest variability of 5HT 2A R measurement with [ 18 F]-altanserin and PET with arterial blood sampling has been reported in several studies.…”
Section: Introductionmentioning
confidence: 99%
“…Test-retest variability of 5HT 2A R measurement with [ 18 F]-altanserin and PET with arterial blood sampling has been reported in several studies. Soares et al reported high mean intra-subject % change of 11–14% for cortical brain areas for the ratio of specific to non-displaceable brain uptakes and the ratio of specific brain uptake to total parent plasma concentration [21]. A four compartment mode tracer kinetic model yielded average differences of 13% or less in regions of high receptor concentrations and 16–20% for regions of low receptor concentrations.…”
Section: Introductionmentioning
confidence: 99%