1996
DOI: 10.1002/(sici)1099-1492(199608)9:5<217::aid-nbm419>3.0.co;2-g
|View full text |Cite
|
Sign up to set email alerts
|

Reproducibility of Human Cardiac31P-NMR Spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
5
0

Year Published

1996
1996
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 66 publications
(8 citation statements)
references
References 24 publications
3
5
0
Order By: Relevance
“…We recorded a PCr/ATP of 1.90 ± 0.92 using the AW FT‐MRS method, which is in good agreement with the previous literature values at 1.5, 3, and 7 T 8–10,33 . The AW FT‐MRS method had a CoR of 1.79 and a CoV of 0.48.…”
Section: Discussionsupporting
confidence: 89%
See 1 more Smart Citation
“…We recorded a PCr/ATP of 1.90 ± 0.92 using the AW FT‐MRS method, which is in good agreement with the previous literature values at 1.5, 3, and 7 T 8–10,33 . The AW FT‐MRS method had a CoR of 1.79 and a CoV of 0.48.…”
Section: Discussionsupporting
confidence: 89%
“…Reconstructions that use the AW phase‐encoding scheme are highlighted by the surrounding black box. PCr/ATP values are in the expected range 8–10,33 . ATP, adenosine triphosphate; AW, acquisition‐weighted; fSLAM, fractional SLAM; FT‐MRS, Fourier transform‐based magnetic resonance spectroscopic imaging; PCr, phosphocreatine; SLAM, magnetic resonance spectroscopy with linear algebraic modelling; SLIM, spectral localization by imaging; SNR, signal‐to‐noise ratio.…”
Section: Resultsmentioning
confidence: 99%
“…Single voxel cardiac 31 P-MRS spectra were obtained from the left ventricle with subjects in the supine position as reported previously [9]. A 10 cm coil was fixed on the chest, at the level of the myocardium.…”
Section: Methodsmentioning
confidence: 99%
“…Although the variability of MRS is often cited as a limitation, modern techniques typically yield a variability of 13% for PCr/ATP ratios, which is in the same range as LV volumes and functional assessment on CMR imaging and echocardiography. 67 , 68 , 69 Future developments and technical advances of MRS at higher field strengths aim to deliver substantial further improvements to make the method valuable for clinical practice.
Figure 5 Pyruvate Metabolism Hyperpolarization imaging helps in investigating the metabolic fate of the first carbon atom (blue) when pyruvate is metabolized to alanine via alanine transaminase (ALT), to lactate via lactate dehydrogenase (LDH), and to bicarbonate via pyruvate dehydrogenase (PDH).
…”
Section: Metabolic Alterations In As and Their Assessment With The Us...mentioning
confidence: 99%