2019
DOI: 10.1016/j.xphs.2018.11.018
|View full text |Cite
|
Sign up to set email alerts
|

Representative Scale-Down Lyophilization Cycle Development Using a Seven-Vial Freeze-Dryer (MicroFD®)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 35 publications
0
10
0
Order By: Relevance
“…(1) If we carry out a gravimetric test in the micro freeze-dryer to get K v , using ring temperature offset in the range À1 C to À5 C, the value we obtain is close to the mean value of a larger-scale unit; (2) If we carry out also a test in the pilot-and commercial-scale unit to get the value of K v , it is possible to tune the ring temperature offset in the micro freeze-dryer to replicate with higher accuracy the product dynamics. This issue was discussed in the study by Goldman et al 27 and, thus, is not further discussed here.…”
Section: Determination Of Model Parameters K V and R Pmentioning
confidence: 89%
See 3 more Smart Citations
“…(1) If we carry out a gravimetric test in the micro freeze-dryer to get K v , using ring temperature offset in the range À1 C to À5 C, the value we obtain is close to the mean value of a larger-scale unit; (2) If we carry out also a test in the pilot-and commercial-scale unit to get the value of K v , it is possible to tune the ring temperature offset in the micro freeze-dryer to replicate with higher accuracy the product dynamics. This issue was discussed in the study by Goldman et al 27 and, thus, is not further discussed here.…”
Section: Determination Of Model Parameters K V and R Pmentioning
confidence: 89%
“…A different system was proposed by Thompson et al 26 and investigated by Goldman et al 27 and by Fissore et al 28 This device (MicroFD®) uses a completely different approach to get uniformity (of temperature and drying rate) in the small-scale batch, minimizing (and even canceling) the edge effect. In this system, the batch of vials is surrounded by an aluminum ring in contact with the external vials of the batch.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…radiation from chamber walls and door (19), while gravimetric test provides a very detailed picture of the system. As far as R p is concerned, it may be estimated as well as by means of PRT-based algorithms (23,28), through TDLAS (29), or using the product temperature measurement in a run (30).…”
Section: Introductionmentioning
confidence: 99%