2020
DOI: 10.2172/1764146
|View full text |Cite
|
Sign up to set email alerts
|

Report on Single and Multiple Intrabeam Scattering Measurements in IOTA Ring in Fermilab

Abstract: The study of single and multiple intrabeam scattering was carried out in the IOTA ring at Fermilab. The report discusses the results of the measurements and outlines still unresolved problems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
6
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
3
2
2

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 0 publications
1
6
0
Order By: Relevance
“…Additional negative effects include the errors in the light focusing optics, calibration errors of the SLMs, and possible Twiss beta-function errors. The SLMs at locations with larger beta-functions (M4L, M1L) provide estimates for y that agree better with the theoretical predictions [42] at lower beam currents, and with the emittance estimates presented below in this paper. Nevertheless, we cannot state that the SLMs could provide a reliable estimate for y during our experiment.…”
Section: Measurement Resultssupporting
confidence: 86%
See 2 more Smart Citations
“…Additional negative effects include the errors in the light focusing optics, calibration errors of the SLMs, and possible Twiss beta-function errors. The SLMs at locations with larger beta-functions (M4L, M1L) provide estimates for y that agree better with the theoretical predictions [42] at lower beam currents, and with the emittance estimates presented below in this paper. Nevertheless, we cannot state that the SLMs could provide a reliable estimate for y during our experiment.…”
Section: Measurement Resultssupporting
confidence: 86%
“…Typically, the combined population of the remaining 3 buckets was no more than a few percent. At the beam currents studied in our experiment (1-3 mA), the beam lifetime is determined solely by Touschek scattering [42,44]. In general, the momentum acceptance is a function of the position along the ring.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…In the first case, we consider a strongly coupled [27,28] transverse focusing optics in IOTA, which was specifically designed to keep the two mode emittances equal 1 = 2 = . This was empirically confirmed to be true with a few percent precision.…”
mentioning
confidence: 99%
“…The vertical emittance y of the flat beam in IOTA could also be estimated from the measured beam lifetime |I/( dI/dt )|, assuming that it is determined solely by Touschek scattering [32], which is a good approximation at beam currents I > ∼ 0.5 mA [28]. In storage rings, the Touschek lifetime is determined by the effective momentum acceptance δ (eff) acc [33], which is smaller than or equal to the rf bucket half-height, δ rf = 2.8 × 10 −3 in IOTA.…”
mentioning
confidence: 99%