2017
DOI: 10.1088/1361-6498/aa604b
|View full text |Cite
|
Sign up to set email alerts
|

Report of IRPA task group on the impact of the eye lens dose limits

Abstract: In 2012 IRPA established a task group (TG) to identify key issues in the implementation of the revised eye lens dose limit. The TG reported its conclusions in 2013. In January 2015, IRPA asked the TG to review progress with the implementation of the recommendations from the early report and to collate current practitioner experience. This report presents the results of a survey on the view of the IRPA professionals on the new limit to the lens of the eye and on the wider issue of tissue reactions. Recommendati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
37
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(38 citation statements)
references
References 9 publications
(5 reference statements)
1
37
0
Order By: Relevance
“…(118) ICRU (1992) recommended the use of the operational quantity, personal dose equivalent H p (3), for dosimetry of the lens of the eye. However, while H p (3) is well suited to assess dose to the lens of the eye, calibration of dosimeters in H p (3) is not available in many countries (Cantone et al, 2017). In Publications 103 (ICRP, 2007a, Annex B) and 116 (ICRP, 2010b), it is recommended that the operational quantity H p (0.07) is adequate for monitoring the lens of the eye for photon exposures.…”
Section: Recommended Option For the Assessment Of Effective Dosementioning
confidence: 99%
“…(118) ICRU (1992) recommended the use of the operational quantity, personal dose equivalent H p (3), for dosimetry of the lens of the eye. However, while H p (3) is well suited to assess dose to the lens of the eye, calibration of dosimeters in H p (3) is not available in many countries (Cantone et al, 2017). In Publications 103 (ICRP, 2007a, Annex B) and 116 (ICRP, 2010b), it is recommended that the operational quantity H p (0.07) is adequate for monitoring the lens of the eye for photon exposures.…”
Section: Recommended Option For the Assessment Of Effective Dosementioning
confidence: 99%
“…8 In addition, guidelines for protective devices according to exposure levels were provided. 9 As the lens dosage cannot be measured directly, ICRP recommends that the most accurate method is the measurement of H p (3), which is the individual dose at a depth of 3 mm, corresponding to the most radiosensitive region. 10 Dosimeters specifically designed to measure H p (3) should be located as close to the eye as possible.…”
Section: Introductionmentioning
confidence: 99%
“…When considering the use of a particular intraoperative imaging modality in spine surgery, radiation exposure to the patient and operating room staff is a concern 11 . The International Commission on Radiological Protection recommends less than 5 Rem per year of the total body exposure and 50 Rem per year of the extremity exposure 12 . Radiation to the surgeon and OR staff is highly variable and dependent on several factors including surgeon and fluoroscopy technician experience.…”
Section: Discussionmentioning
confidence: 99%